Installation Instructions, Viper 2000 Control System

PRD0167E01en

UWE Verken AB

3(6)

Footnotes

1.

If the flap motor drive has an additional position 
feedback, the flaps can be positioned in a 
selectable number of intermediate positions. If left 
unconnected the flaps will go all the way to their 
respective mechanical stop positions.

2.

This option is added for the case that analog 
positioning of valve control motors is required. If a 
single solenoid is to be used - connect the coil 
between ground and either the inverted or non-
inverted output.

3.

These outputs are added in order to make it 
possible to use only the control unit as a 
compartment controller.

4.

The feedback potentiometers can be connected 
directly between GND and +24V. Variations of 
supply voltage are internally compensated.

Relay + AC : CO2 12 pole

AC Ice detection

<5V = Ice

CO2:1

Digital input

AC HP

In series with Clutch activation

CO2:2

Digital input

AC LP

In series with Clutch activation

CO2:3

Digital input

Defroster fan speed 2

Relay driver output

CO2:4

Solid state outp. 1.9A

Defroster fan speed 3

Relay driver output

CO2:5

Solid state outp. 1.9A

AC OverTemp

<5V = Compr. over tmp

CO2:6

Digital input

AC Condenser fan

Contactor driver

CO2:7

Solid state outp. 2.2A

Defroster fan speed 1

Relay driver output

CO2:8

Solid state outp.1.9A

Defroster fan speed PWM +

20 kHz Duty Cycle modulated   differential 
output for direct interface with PWM switch. 
NonInv.

CO2:9

EIA RS485 transmitter out-
put. 15kV ESD protection, 
slew rate limited.

AC Compressor Clutch

Direct drive

CO2:10

Solid state outp. 5.7A

Whisper heating fan (Rec. Blower)

Relay driver output

CO2:11

Solid state outp. 1.9A

Defroster fan speed PWM -

As CO2:9 Inverted

CO2:12

As CO2:9

Power Communication: CO3 9 pole

Recirculation blower for guide

Relay driver output

3) 

CO3:1

Solid state outp. 1.9A

Booster pump

Relay driver output

3) 

CO3:2

Solid state outp. 1.9A

Auxilliary Heater

Relay driver output

3) 

CO3:3

Solid state outp. 1.9A

Batt+

/ Standby

CO3:4

Power 10A / 30mA

Gen

>7V = Engine running

CO3:5

Digital input

CAN L

Transceiver PCA82C251

CO3:6

Communication Line

GND

Chassies Ground

CO3:7

POWER GND

Master Switch (+30) / System wake up

CO3:8

Power input 1A

CAN H

Transceiver PCA82C251

CO3:9

Communication Line

Table 1: Display unit

Description

Comment

See 
footnote

Pin

Type

Summary of Contents for Viper 2000

Page 1: ...ferably in a way that a minimum of sunlight is reflected in the display To mount the sensors see separate installation sheet PRD0070 Ensure that the control units are placed at a place pro tected from water Structure of the control system Example of structure in an articulated bus Drivers place Climate zone 1 Climate zone 2 Drivers place temperature Outside temperature Defroster temperature Flap F...

Page 2: ...sensor Defroster air CO1 5 Analog NTC 4 7kΩ Valve Defroster circuit position feed back Open High Voltage 2 4 CO1 6 Analog 0 33V Flap Fresh Recirc defroster air Rec 24V Source sink CO1 7 Solid state outp 1 9A Valve Driver s Convector circuit pos feedback Open High Voltage 2 4 CO1 8 Analog 0 33V Temp sensor GND defroster air CO1 9 Sensor ground Flap Fresh Recirc defroster air Rec 0V Source sink CO1 ...

Page 3: ...ster fan speed 3 Relay driver output CO2 5 Solid state outp 1 9A AC OverTemp 5V Compr over tmp CO2 6 Digital input AC Condenser fan Contactor driver CO2 7 Solid state outp 2 2A Defroster fan speed 1 Relay driver output CO2 8 Solid state outp 1 9A Defroster fan speed PWM 20 kHz Duty Cycle modulated differential output for direct interface with PWM switch NonInv CO2 9 EIA RS485 transmitter out put 1...

Page 4: ...O1 7 Solid state outp 1 9A Temp sensor GND Ventilation air CO1 8 Sensor ground Temp sensor Ventilation air CO1 9 Analog NTC 4 7kΩ Valve Convector circuit Open 24V Direct Drive Motor valve driver Non inverted 2 CO1 10 Solid state outp 1 9A Valve Convector circuit Open 0V Direct Drive Motor valve driver Inverted 2 CO1 11 Solid state outp 1 9A Flap Fresh Rec Vent air pos feedb Left side 1 4 CO1 12 An...

Page 5: ...olid state outp 1 9A AC Lp In series with Clutch activation CO2 3 Digital input Vent fan speed 1 Relay driver output CO2 4 Solid state outp 1 9A AC OverTemp 5V Compr over tmp CO2 5 Digital input AC Hp In series with Clutch activation CO2 6 Digital input AC Condenser fan Contactor driver CO2 7 Solid state outp 2 2A AC Compr Clutch Direct drive CO2 8 Solid state outp 5 7A AC Ice detection 5V Ice CO2...

Page 6: ...drive capability is a hardware option that can be delivered on request Since no single input pin can carry a load of more than 10A additional Batt connections has to be done 6 If no high current drivers are used only one of these outputs need to be used If only one high curren driver is used two of these has to be connected and if two or more are used all three supply pins should be connected AMP ...

Reviews: