The TIMER mode allows the user to choose the UV light emission time manually thanks to the TIMER located on the 
front panel. TIMER parameters can be locked thanks to the key. In the standard version, the time can be adjusted 
between 1 second and 99 minutes 99 seconds. For other time range, feel free to contact us. It also allows the user to 
control the UV LED lamp thanks to a PLC.  

1.

 

Manually: 

 

Verify that the two “schunt” connectors are plugged on “chiller” and “PLC” M12 5pins connectors at the 

back panel.  

 

Choose the UV light intensity between 20% and 99% thanks to the potentiometer.  

 

Adjust the insolation time thanks to the arrows on the TIMER (orange display). Push the “RESET” button to 

validate the insolation time. Then, the time is displayed in red above the orange display.   

 

Launch UV light emission by pushing the START button. Then, the time is elapsing (red display). When the 
insolation time is finished, the UV light emission stops.  

 

Press STOP to switch off the light in case of an emergency. When this button is engaged, you must disengage 
it to allow UV light emission.   
 

2.

 

With a PLC: 

 

Verify that the “chiller” security is not activated 

(water circulation) 

or use a “schunt” connector on the 

“chiller” M12 5 pins connector at the back panel.  

 

 

Choose the UV light intensity between 20% and 99% thanks to the potentiometer.  

 

Adjust the insolation time thanks to the arrows on the TIMER (orange display). Push the “RESET” button to 

validate the insolation time. Then, the time is displayed in red above the orange display.   

 

The PLC can allow 

UV light emission thanks to the dry contact between pin1 and pin3 on the “PLC” M12 

connector at the back panel (please refer to the electrical scheme of page 6).   

 

The user can also use the 

PLC

 M12 5 pins connector at the back panel to launch the TIMER externally (PLC 

or footswitch). Then, the time is elapsing (red display). When the insolation time is finished, the UV light 
emission stops. Please refer to the electrical scheme on page 6, dry contact between pin 4 and pin 5. 

 

Press STOP to switch off the light in case of an emergency. When this button is engaged, you must disengage 
it to allow UV light emission.  

 

 

 

TIMER MODE 

Summary of Contents for UPOWER-3000-48

Page 1: ...such as smoking abnormal heating abnormal odor or noise occurs stop using the control unit immediately and turn OFF the power switch Continued use may result in fire or electric shock Do not place the control unit in direct sunlight or in a very humid environment Doing so may result in fire due to internal temperature rise Observe the limitations of the operating temperature and humidity Do not in...

Page 2: ... 1 Rue de Terre Neuve 91940 LES ULIS FRANCE Tel 33 9 72 52 70 03 Fax 33 9 72 11 21 69 Email contact uwave fr Page 2 9 Table of contents 1 3 4 5 7 8 9 Security of the user Technical overview Names and functions of parts Quick start ON OFF MODE TIMER MODE Mechanical dimensions mm ...

Page 3: ...r delivered 3000 W Input power Single phase 180 to 264 VAC 50 60 Hz Connector to 220V IEC C14 Output voltage and current 48 VDC and 63 A for one Channel Connectors to UV products M12 8 pins female x1 EPIC 4 pins female x1 Inrush current typ 60 A at 230 VAC Ground leakage current 2 mA max at 240 VAC Mechanics W L H mm 340mm 460mm 120mm Weight 10 kg Material Device body Aluminum alloy Environment Wo...

Page 4: ...y 20 Miniparc du Verger Bâtiment E 1 Rue de Terre Neuve 91940 LES ULIS FRANCE Tel 33 9 72 52 70 03 Fax 33 9 72 11 21 69 Email contact uwave fr Page 4 9 Front side UPOWER FAV 3000 TIMER Rear side UPOWER FAR 3000 TIMER Names and functions of parts ...

Page 5: ...ection both sides of the cable must be screwed 3 The M12 5 pins connector on the rear side named CHILLER is a security for water cooled UV LED lamps The control unit waits for a signal from the chiller in order to allow UV light emission If this step is not realized the UV LED lamp will not switch on Plug the water pipes from the chiller to the UV LED lamp and the M12 5 pins cable from the chiller...

Page 6: ...he electrical scheme below to install an external communication PLC Pin number Color Type Function 1 Brown out 24 VDC 2 White Out 0V GND 3 Blue In 0 VDC UV emission not allowed 24 VDC UV emission allowed 4 Black START TIMER 5 Blue START TIMER M12 connector scheme on the left and Schunt picture on the right 5 Connect the power cable into the IEC C14 connector and into the wall Then the power switch...

Page 7: ...tiometer Launch UV light emission by pushing the START button and press START again to stop it Press STOP to switch off the light in case of an emergency When this button is engaged you must disengage it to allow UV light emission 2 With a PLC Verify that the chiller security is not activated water circulation or use a schunt connector on the chiller M12 5 pins connector at the back panel Choose t...

Page 8: ...en the insolation time is finished the UV light emission stops Press STOP to switch off the light in case of an emergency When this button is engaged you must disengage it to allow UV light emission 2 With a PLC Verify that the chiller security is not activated water circulation or use a schunt connector on the chiller M12 5 pins connector at the back panel Choose the UV light intensity between 20...

Page 9: ...UPOWER 3000 48 Version 2 1 MAJ July 20 Miniparc du Verger Bâtiment E 1 Rue de Terre Neuve 91940 LES ULIS FRANCE Tel 33 9 72 52 70 03 Fax 33 9 72 11 21 69 Email contact uwave fr Page 9 9 Mechanical dimensions mm ...

Reviews: