UVP701C

Professional Intelligent UV & Ozone Generator

24W UVC bulb

 

254nm UVC

Work light specifications

Irradiance:

2340μW/cm²

UVC gen: 120W

Ozone gen: 320W

Output

10.6 kg

IP20

60mg/m³

28ppm

UVC gen

 

230x141x440mm

Ozone gen

365x297x168mm

Summary of Contents for UVP701C

Page 1: ...ssional Intelligent UV Ozone Generator 24W UVC bulb 254nm UVC Work light specifications Irradiance 2340μW cm UVC gen 120W Ozone gen 320W Output 10 6 kg IP20 60mg m 28ppm UVC gen 230x141x440mm Ozone gen 365x297x168mm ...

Page 2: ...nerator can be combined or independently used With the intelligent button operation interface the user is able to independently select and adjust the disinfection mode and disinfection time Color LCD screen can display the information e g disinfection mode disinfection time etc The disinfection cabinet has a memory function After each power on the screen shows the preset mode and time of the last ...

Page 3: ...dy Sensing system startsautomatically it will automatically stop disinfection operation immediately if it detects thereare people moving around the equipment at the same time the screen will show markto show that machine has stopped due to close proximity of personnel 6 Long press OK button for 1 5s to stop the disinfection session the timer will return to initialsetting B Ozone generator standalo...

Page 4: ...t hands in operating the product Please keep the operating environment dry 7 Do not remove repair and alter the product by oneself Repairs and battery replacements can only be carried out by authorized service providers and manufacturers and repair and replacement of batteries by authorized service providers and personnel other than manufacturers may result in injury Replacing the battery with the...

Page 5: ...tion in the workplace i e occupational exposure limit is 0 1PPM 8 The amount of space used by the equipment used to place and use this device should not be less than 20m to ensure that the ozone remaining in the equipment has sufficient space to be decomposed to a safe level when the cabinet door is opened 9 When opening the equipment for ozone disinfection make sure that the equipment is in a wel...

Page 6: ...ll bacterial spores The radiation dose should not be less than 100 000 μW cm when the target microorganism for disinfection is unknown 3 According to the radiation intensity of the UV light source of this product and the general distance of the UV light source from the irradiated object it is recommended that In order to achieve the radiation dose of 10 000 μW cm to meet the general needs of daily...

Page 7: ...tested on stainless steel aluminum gold plated PIN needles silicone cotton pads cotton and ABS plastics and no significant decomposition was found 6 It is recommended to avoid ozone disinfection of brightly colored leather silk and other items Some highly aged items such as natural rubber are also recommended to not undergo ozone disinfection Since ozone has an oxidative effect on most metals user...

Page 8: ...V C emitted from this product Avoid eye and skin exposure to unshielded product Follow installation instructions and user manual www uvpluss com Breakable Glass Hazard Can cause personal injury Be careful when inserting bulb s into lamp base Wear protective gloves when handling bulb s OZONE can cause color shift or structural degradation of leatherwear High concentrations of ozone for a long time ...