background image

2

SAFETY

GENERAL SAFETY RULES AND PRECAUTIONS

WARNING! READ AND UNDERSTAND ALL INSTRUCTIONS

Failure to follow all instructions listed may result in serious injury.

Meaning of Special Language

CAUTION: 

Procedures, which if not properly followed, create the probability of serious physical injury.

W

ARNING: 

Procedures, which if not properly followed, create the probability of serious injury OR create 

a high probability of superficial injur .

Failur

e to operate the product correctly can result in damage to the product, 

Personal property and cause serious injury

.

WORKPLACE AND PERSONAL SAFETY

•  Mobile units with casters should only be used for intended

purpose; it is intended for secondary cleaning only, primary

cleaning to remove foreign materials (e.g.,dust, soil) and

organic materials (e.g., blood, secretions, excretions) must

be done first.

•  This product is for indoor use only to decontaminate an area

using UVC light.

• Do not use device if it is damaged this may cause injuries

contact UVC Cleaning Systems for repair.

•  Unprotected exposure to UVC light can cause injuries that

may include but are not limited to damage to eyes and skin.

Always ensure that the intended treatment space is NOT

occupied by any person or animals for any reason. Keep

bystanders, children, visitors and pets away from the device

and out of room while operating equipment.

•  Do not use equipment while tired or under the influence of

drugs, alcohol, or medication.

•  Operate in an enclosed, non-occupied area only. Windows

and doors must be closed during equipment operation.

•  Post warning signs in a conspicuous place where everyone

can see them to prevent a person from entering the area

when operating the equipment 

“Do Not Enter – UVC

T

reatment in Progress. Danger do not expose eyes or

skin to UVC radiation ”. Be sure to display “Do not enter

– T

reatment in Progress”

 signs at all access points to the

room. This ensures that no people will enter the room while

the UVC treatment is in progress.

•  Store UVC Cleaning System devices out of the reach of

children and other untrained personal when not in use.

•  UVC Cleaning Systems equipment should never be

disassembled, opened or altered by the user. This could

create a safety issue and will void the warranty and violate

the lease agreement with UVC Cleaning Systems.

• Use light blocking material on visible gaps greater than 1/2

inch in the door seal or at the bottom of the door. No visible

light should escape the desired treatment area. Gaps in the

door seal could cause a risk of damage to eyes and skin.

•  When transporting, push or pull UVC Cleaning System

devices using only the handles located on the outside of

 

the

cage.

•  Safezone 850M

ax

 should never be left unattended on an

incline.

•  UVC Cleaning System devices are heavy and weigh

approximately 4

0

 lbs. They will require adequate strength to

maintain control of the equipment during transportation.

•  Never operate more than two Safezone 850M

ax

 UVC

Cleaning System devices on a single 15AMP circuit. The

Safezone 850M

ax

 UVC Cleaning System device requires a

dedicated 15 amp circuit to operate dual units. A single

Ssafezone 850M

ax

 UVC Cleaning System device requires a

7.5 amp circuit or greater to operate.

•  It is not recommended to operate UVC Cleaning System

s

devices using an extension cord.

•  If lamps are broken or damaged, follow clean up procedures

found in this document and call UVC Cleaning Systems

immediately.

•  Do not remove safety labels, they are there for your

protection.

•  Always inspect power cord before use, if power cord is

damaged, do not operate, call UVC Cleaning Systems

immediately.

•  Do not touch lamps or metal cage after operation. Lamps

 

will

be hot!

Summary of Contents for SAFEZONE 850MAX

Page 1: ...1 Phone 810 358 7202 E mail Support UVC INC com Skype UVC INC UVC DECONTAMINATION DEVICE SAFEZONE USER MANUAL For Models SAFEZONE 850MAX DECONTAMINATION...

Page 2: ...ogress Danger do not expose eyes or skin to UVC radiation Be sure to display Do not enter Treatment in Progress signs at all access points to the room This ensures that no people will enter the room w...

Page 3: ...ons and situations that may arise or occur It must be understood by the operator that caution must be used when operating a high powered electrical device 6 ems ish Product Label This label is is loca...

Page 4: ...lpful tools as you get familiar with your unit Do Not Enter Signs The safety warning door sign should be displayed on all entry points to the area that is being treated Its purpose is to inform others...

Page 5: ...bility Model Safezone 850M9 without base Characteristic Specification Application This mobile device is for indoor use only to disinfect an area using high intensity UVC Light Height 41 5 105 4cm Widt...

Page 6: ...haracteristic Specification Height 6 0 152 mm Width 1 5 38 mm Depth 1 26 mm Weight 4 5 oz Construction ABS Plastic Power Requirements 1 9V battery 9 Volts Label Matched unit label on back Model Overvi...

Page 7: ...you are treating Remote Control The remote comes fully assembled and linked to the unit The range on the remote is about 50 ft through one wall The life of the battery is 3 6 months or longer dependi...

Page 8: ...impact protection if necessary The power cord should be coiled around the cord wrap on the cage of the unit while transporting The Safezone 850 Max is equipped with an aluminum rolling base The unit i...

Page 9: ...t use UVC Cleaning System devices and contact UVC Cleaning Systems It is safe to run two Safezone 850 Max units off one one dedicated 15 amp circuit Operating Procedures Single Unit Operations UVC Cle...

Page 10: ...Systems distributor The customer should never disassemble repair or replace any parts on the device Service is only performed by a qualified representative of UVC Cleaning Systems Inc Failure to follo...

Page 11: ...ened or altered by the user This could create a safety issue and will void the warranty and violate the lease agreement with UVC Cleaning Systems Flip the unit upside down to read the number of operat...

Page 12: ...uipment could lead to risk of fire shock and bodily harm Remote out of radio frequency range The Remote Control has a 15M 50ft range The Remote Control will stay in the same state when out of range an...

Page 13: ...value our customers and will continually evolve to support the infection control industry and our customers needs UVC Cleaning Systems Inc offers technologically advanced and cost effective decontamin...