UTS 700 STAIRWELL INSTRUCTION MANUAL
Page 6
LADDER LOCKING CLIPS
Ensure ladder clip is locked into position by
pushing all the way until lock clicks out.
CORRECT FITTING OF
LADDER
Ensure ladder is clipped top and bottom
between the locating rings on the rung.
CORRECT FITTING OF
HORIZONTAL BRACING
THE CORRECT FITTING OF HORIZONTAL
BRACING IS IMPORTANT.
The diagrams opposite illustrate the CORRECT
brace positions.
REMEMBER: Always fit braces DOWNWARD
or from the inside facing OUTWARD –
BUT
NEVER INWARD
FITTING ADJUSTABLE
BASE FEET
Take the adjustable leg assembly complete with its
base plates, make sure that all the adjusting nuts are
positioned down at the plate and slide them into the
vertical tube, turn the base unit the right way up and
with the aid of a spirit level placed on the platform, the
adjusting nuts can be used to level the structure. (and
not to gain additional height).
BRACE CLAMP LOCKING
Ensure that the brace clamp is locked as shown.
Always make sure the brace is not clamped too
close to the weld as indicated by the arrow on
the drawing on the right.
Un
-
Locked
Locked
✓
✓
Un
-
Locked
Locked