background image

There are totally 8 different web pages.
Three are for the users, index.htm, reset.htm and rs232

The remaining five pages are for configuration of the box and is reached only by admin, they are:

config.htm:

For configuration of IP address, port number, title at the user pages, basic or digest
authorization, and the time the box is reserved for

one

user.

switches.htm:

Here the names of the 8 ON/OFF buttons and the delays at power on and the reset delays
is configured.

users.htm:

Here is usernames and passwords for the 8 users + admin and Telnet is configured.

rights.htm:

Here access rights are configured for all user 1 to 3 and for those not logged in.

r2.htm:

Here access rights are configured for users 4 to 8.

2. The main page.

The main page (index.htm) is used to switch the outputs ON/OFF..

When you click at the ON or OFF button a
request for this is sent to the box.
Then the button turns gray until the box has
confirmed the change. When the confirmation
arrives the button indicates current setting again.
In this way you can be sure that the change
request actually has reached the box and been
serviced.

If you click at "refresh screen" then a question
about current status is sent to the box. The
buttons turns gray until the reply is received. This
is particular useful when many user control the
box.

In some cases you might like to switch more
than one output at exactly the same time. The
you untick the box "update box on change".
The nothing is sent to the box until you click
the button "update box".

The digits 1 to 16 above the ON/OFF buttons
may be replace by your own text. This is done
at the configuration page switches.htm.
A title at top of the page can be configured at
the page config.htm.
These changes can only be done after you have
logged in as admin, as described in the
configuration part below.

Summary of Contents for IP-SwitchBox902

Page 1: ...he outputs On the reset page reset htm there are in addition buttons to make a temporary switching off for a specified time This time can be configured for each output At power on the outputs are swit...

Page 2: ...he ON or OFF button a request for this is sent to the box Then the button turns gray until the box has confirmed the change When the confirmation arrives the button indicates current setting again In...

Page 3: ...s controlled by IP SwitchBox 902 and is hence not dependent of any delays on the internet The time is configured at the configuration page switches htm These changes can only be done after you have lo...

Page 4: ...sly with this username This is the small Telnet client for the web browser At the page RS232 htm there are a small Telnet client It is a Java applet that starts when you load the page In this way you...

Page 5: ...Without title the username will not be showed You can configure a title with a blank only to get the username only at the top the pages RARP BOOTP By setting the IP address to 0 0 0 0 the IP address i...

Page 6: ...ers With up to 7 characters the layout of the page will be unchanged Turn on delay is used to delay switch on of the outputs for up to 10 minutes after power failure This is to activate the outputs in...

Page 7: ...and passwords for all 8 users and for admin and telnet The characters A Z a z and 0 9 may be used By leaving it blank at one Login the number of users are reduced by one By leaving it blank at Passwo...

Page 8: ...sent position is showed with slightly grayed ON OFF buttons The outputs can not be changed r w read write Present position is showed with normal ON OFF buttons The outputs can be changed 6 The RS232 p...

Page 9: ...parity one stop bit no handshake Connection to a PC is done with a straight cable that is with pin 1 to pin 1 2 to 2 etc The control commands are Switch on output x ONxx example ON01 Switch off outpu...

Page 10: ...tc S1 0 2 Specify delay for output 1 at power on etc A wwrrnnnnr Specify the access rights for up to 8 users those not logged in ninth user w read and write rights r read rights n no rights Z Prints t...

Page 11: ...oups it is easyer to read 4031 0000 FFFF 100F 1234 0 Control To control the box a http request for k1aaaabbbbccccdddd is sent Where a b c d are the parameters aaaa Bit mask for switch on Four bytes of...

Page 12: ...ble to run the script in Windows environment by using for example ActivePerl On the CD there are also an example in Visual Basic 10 Default settings IP address 10 195 70 218 Port http 80 Port telnet 2...

Page 13: ...same connector The difference between in and outgoing 48V is that the box gets its power supply from the in going 48V It is sufficient if 48V is available on one of the ingoing 48V connections to make...

Page 14: ...e the setup menu by pushing q like quit to control the box in normal way b Connect IP SwitchBox902 to the network The supplied blue cable is a straight cable that is used for connection to hubs the mo...

Reviews: