background image

 

 

 

 

Lowes.com 

Additional Safety Precautions 

1.  Know the pump applications, limitations, and potential hazards. 
2.  Make certain the electrical power source is adequate for the requirements of the pump. 
3.  ALWAYS disconnect the power to the pump and drain all water from the system before 

servicing. 

4.  Secure the pump on a solid base to keep the pump vertical and above mud and sand during 

operation to maximize pumping efficiency and prevent clogging and premature pump failure. 

5.  Secure the discharge hose before starting the pump. Pump torque may cause an unsecured 

discharge hose to “whip”, possibly causing personal injury and/or property damage. 

6.  Before using the pump, check hose for holes or excess wear, which could cause leaks, and be 

sure hose is not kinked or making sharp angles. A straight hose allows the pump to move the 
greatest amount of water quickly. 

7.  Check that all hose connections are tight to minimize leaks. 
8.  Connect the pump DIRECTLY to a grounded, GFCI outlet. 
9.  Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present 

a life-threatening safety hazard if the insulation becomes damaged or the connection ends fall 
into water. 

10. Make certain the electrical circuit to the pump is protected by a 10-amp or larger fuse or circuit 

breaker. 

11. Periodically inspect pump and system components, to be sure pump inlets are free of mud, 

sand, and debris. DISCONNECT PUMP FROM THE POWER SUPPLY BEFORE 
INSPECTING. 

12. Wear safety glasses at all times when working with pumps. 
13. Follow all electrical and safety codes, particularly the National Electrical Code (NEC) and in the 

workplace, the Occupational Safety and Health Act (OSHA). 

14. This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an 

approved 3-conductor cord and 3-prong grounded plug. DO NOT REMOVE THE GROUND 
PIN UNDER ANY CIRCUMSTANCES. The 3-prong plug must be directly inserted into a 
properly installed and grounded 3-prong, grounding-type receptacle. 

Do

 

not use pump with a 

2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle (

GFCI outlet

) installed in accordance with the National Electrical Code and local codes and 

ordinances. All wiring should be performed by a qualified electrician. 

15. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking 

the cord. 

Do not use damaged or worn cords. 

 

PERFORMANCE                                                                        

 

Model 

HP 

GPM of Water at Total Feet of Head with 3/4 in. hose 

 

5 ft. 

10 ft. 

15 ft. 

20 ft. 

25 ft. 

Maximum Lift 

PPSU33 

1/3 

21 

17 

12 

28 ft. 

 
For best performance, the maximum recommended hose length is 50 ft. The pumping capacity or 
water flow rate of any pump depends on several factors. The larger the inside diameter and the 
shorter the length of hose, the less pressure that is lost (or the larger the flow rate). The maximum 
pressure produced by this pump is about 13 PSI. If the hose runs uphill or is extra-long, use a 
larger diameter hose or rigid pipe. 

Summary of Contents for PPSU33

Page 1: ...iption Quantity A Pump 1 B Adaptor 1 ATTACH YOUR RECEIPT HERE Serial Number ______________________ Purchase Date___________________________ Questions problems missing parts Before returning to your retailer call our customer service department at 1 866 994 4148 8 a m 8 p m EST Monday Friday A B Lowes com ...

Page 2: ...mp minimum Operating water depth beginning minimum approximately 1 1 2 in Ending water level max approximately 1 4 in Discharge connection 3 4 in garden hose thread or 1 1 4 in hose with included adaptor 1 in garden hose if attaching directly to the pump Discharge hose diameter 3 4 in minimum I D Discharge hose length 50 ft maximum recommended hose length Motor Permanent Split Capacitor with therm...

Page 3: ... applications It can drain or remove water from the following pits sinks window wells basements swimming pool covers boats low spots in yards or other flooded areas This pump has not been tested or approved for use in swimming pools or in salt water marine areas This pump is made of high strength corrosion resistant materials It will provide trouble free service for many years when properly instal...

Page 4: ...sand and debris DISCONNECT PUMP FROM THE POWER SUPPLY BEFORE INSPECTING 12 Wear safety glasses at all times when working with pumps 13 Follow all electrical and safety codes particularly the National Electrical Code NEC and in the workplace the Occupational Safety and Health Act OSHA 14 This unit is designed only for use on 115 volts single phase 60 Hz and is equipped with an approved 3 conductor ...

Page 5: ... hose or power cord Keep the pump inlet screen clear Do not install pump directly on sand or dirt A minimum water level of 1 1 2 in is required to prime the pump INSTALLATION INSTRUCTIONS 1 Attach the included adaptor B to the threads of the pump A Note The adaptor B has a built in check valve The use of this adaptor will prevent the backflow of water into the pump A 2 Connect either a 3 4 in gard...

Page 6: ...and check to make sure that water or other debris is not still contacting the sensor probes The pump can remain plugged in and will automatically turn back on when water reaches approximately 1 1 2 in again AIRLOCK This pump A is a centrifugal utility pump designed to efficiently remove water However it cannot move air If air is trapped inside the pump a condition called airlock the pump cannot pu...

Page 7: ... two stainless screws 6 and remove the sensor probe housing 7 There will be metal probes inside this housing Gently clean off these probes with a small brush not included and dry the probes Reassemble TROUBLESHOOTING If you have any questions regarding the product please call customer service at 1 866 994 4148 8 a m 8 p m EST Monday Friday Note Do not disassemble the motor housing This motor has N...

Page 8: ...nd fitness for a particular purpose 3 In no event shall the distributor be liable for consequential incidental or special damages resulting from or related in any manner to any distributor components or accessories 4 The distributor disclaims all liability for improper installation or improper use of this product Some states do not allow the exclusion or limitation of incidental or consequential d...

Page 9: ... Bomba 1 B Adaptador 1 ADJUNTE SU RECIBO AQUí Número de serie______________________ Fecha de compra ________________________ Preguntas problemas piezas faltantes Antes de volver a la tienda llame a nuestro Departamento de Servicio al Cliente al 1 866 994 4148 de lunes a viernes de 8 a m a 8 p m hora estándar del Este A B ...

Page 10: ...ofundidad de agua en funcionamiento mínimo al comienzo Aproximadamente 1 1 2 pulg Nivel de agua al término máx Aproximadamente 1 4 pulg Conexión de descarga Rosca de mangueras para jardín de 3 4 pulg con adaptador incluido Manguera para jardín de 1 pulg si se fija directamenta a la bomba Diámetro de manguera de descarga D I mínimo de 3 4 pulg Largo de manguera de descarga Máximo recomendado de 15 ...

Page 11: ...da para transferir agua desde fosas fregaderos cavidades de ventanas cubiertas de piscinas pisos inundados u otras áreas inundadas Esta bomba no ha sido probada ni aprobada para su uso en piscinas o zonas marinas con agua salada Esta bomba está fabricada de materiales de alta resistencia y resistencia a la corrosión Brindará servicio sin problemas durante muchos años si se instala mantiene y usa a...

Page 12: ...aislamiento o si los extremos de la conexión caen al agua 10 10 Asegúrese de que el circuito eléctrico hacia la bomba esté protegido por un fusible de 10 amperios o más o un interruptor de circuito 11 Inspeccione periódicamente la bomba y los componentes del sistema para asegurarse de que las entradas de la bomba estén libres de arena lodo y desechos DESCONECTE LA BOMBA DEL SUMINISTRO DE ELECTRICI...

Page 13: ...e se enfríe luego de su uso prolongado Antes de comenzar a ensamblar el producto asegúrese de tener todas las piezas Compare las piezas con la lista del contenido del paquete No intente ensamblar el producto si falta alguna pieza o si estas están dañadas Póngase en contacto con el Departamento de Servicio al Cliente para obtener piezas de repuesto Tiempo estimado de ensamblaje instalación nueva 5 ...

Page 14: ... agua debe hacer contacto con las sondas del sensor de la bomba para que esta última se active Cuando la bomba A retire agua hasta aproximadamente 6 35 mm de altura esta seguirá funcionando durante 30 segundos más y luego se apagará o Nota Si la bomba A no se apaga retírela y verifique para asegurarse de que no haya agua u otros residuos que toquen las sondas del sensor La bomba puede permanecer e...

Page 15: ... secas y sin pararse en el agua Al desconectar la alimentación inspeccione las entradas de la bomba y retire todos los desechos luego vuelva a enchufar la bomba al tomacorriente con puesta a tierra GFCI 1 Para destapar una bomba obstruida con desechos primero DESENCHUFE LA BOMBA de la alimentación eléctrica Luego consulte la Imagen 1 a continuación destornille los tornillos inoxidables 1 retire la...

Page 16: ...a manguera más corta 6 Vuelva a ensamblar el impulsor Consulte la sección Cuidado y Mantenimiento 7 Llame al 1 866 994 4148 GARANTíA Este producto está garantizado contra defectos de fabricación por un período de 12 meses a partir de la fecha de compra Cualquier tipo de uso inadecuado abuso o modificación anulan automáticamente esta garantía El distribuidor reparará o reemplazará la bomba si a su ...

Reviews: