The Utile Engineering Co. Ltd.
15/08/06
Irthlingborough, Northamptonshire. England
Tel: +44 (0) 1933 650216
Fax: +44 (0) 1933 652738
5 IC183
Technical Specification
The model and machine serial number appears on the machine data plate, other machine data can be found in the
following table.
Units DSP25-5
Maximum Vacuum
kPa
91.5
Speed – Maximum
R.P.M.
2400
Speed - Minimum
R.P.M.
1200
Capacity at 50kPa at Maximum Speed
L/min
2225
Capacity at 50kPa at Minimum Speed
L/min
950
Absorbed Power at 50kPa at Max. Speed
kW
1.3
Absorbed Power at 50kPa at Min. Speed
kW
0.6
Maximum Inlet Temperature
°
C
40
Temperature Classification
T3
Moment of Inertia
kg m
2
0.001
Noise Level at 1 metre
dB (A)
80
Weight kg
13
Packaging
The packaging conforms to the relevant regulations. The symbols used on the packages are as follows: -
The machines are bolted down, palletised and shrink wrapped for general protection, and therefore should not
move during transportation. The ancillary components are packed suitably within the case. The packaging and
contents should be received in good condition. The contents should be inspected against the advice note, notify
Utile Engineering within 24 hours of any items, which are damaged or are missing.
Storage
If the machine is not required for immediate installation, the machine should be stored in a clean, dry area
protected from the weather. The intake and discharge port covers must remain in position until the machine is
installed. We recommend that until the machine is installed the shaft be turned a few revolutions by hand every
month to ensure the machine is running free.
The green protective coating on the shaft remains effective for approximately 1 year. If the machine is stored for a
longer period of time, the coat must be renewed.
Handling
Skilled personnel working in accordance with safe working practices must carry out the lifting of machines. Before
lifting machines ensure the correct equipment is available. All equipment must be capable of carrying the weight of
the machine to be lifted. Do not use the machine ports or the shaft extension for lifting or moving the machine.
For weights see above in Technical Specification.
Installation
Utile Engineering trained personnel or those trained to an equivalent standard must only carry out installation, any
claims for damage due to faulty installation will be void. All warning instructions and labels must be observed and
retained with the machine.
It is essential equipment is installed, earthed and guarded in accordance with current legislation.
If the user is installing their own switches and safety devices these must be suitable for the correct working area.
The machine is delivered ready to be connected, with only the removal of the intake and discharge protection
covers. Before installation ensure there is no damage to the machine and that it turns freely by hand.
Location
The machine should be installed in a clean, dry, well-ventilated area. Allow adequate space and facilities for
service, inspection and future expansion.