![background image](http://html.mh-extra.com/html/utilco/bll-40-is/bll-40-is_instruction-manual_1065271016.webp)
Pg. 16
BLL-40-IS
11. Battery Status Lights
Fault
Cause / Solution
At the end of the cutting cycle
No light
No malfunction
Red flashing light
Charge / substitute the battery (about 10% of the capacity)
Red light
Flat battery
After inserting the battery
Green light
No malfunction
Red light
Charge /replace the battery
12. Maintenance Requirement Lights
Fault
Cause / Solution
At the end of the cutting cycle
green light
Operating value OK
green/red flashing
Operating value OK and interval of maintenance passed/due
red flashing
Operating value at limit / contact customer service
red light
Operating value faulty or hardware malfunction / request
assistance
orange light
Temperature error / warm or cool the tool
After inserting the battery
green light
No malfunction
orange light
Temperature error / warm or cool the tool
Tool Reset:
The cable cutter turns off and remains blocked. The service red or orange LED‘s light up.
Work can resume only after replacing the battery or after removing it for a moment and
then reinserting it. If after you reset the tool the issue persists contact the customer
service department (see back cover).