background image

TF6P-EU: 6 Buttons IP Control Panel                                                         

 

U.T.E. electronic GmbH & Co. KG   

6

 

 

 

 

 

 

 

www.ute.de 

4. GUI Control 

TF6P-EU provides with built-in GUI for convenient TCP/IP control.   
GUI allows users to interact with TF6P-EU through graphical icons and visual 
indicators. 

 

4.1 

Log in 

The TF6P-EU is controlled by TCP/IP. 

The default IP settings are: 

IP Address:  192.168.0.178 

Subnet Mask:  255.255.255.0 

 

Type 

192.168.0.178 

in your browser, it will enter the log-in interface shown as below: 

 

Username

: admin 

Password

: admin 

Type the username and password, and then click the login to enter the GUI setting. 

 

 

Summary of Contents for TF6P-EU

Page 1: ...www ute de TF6P EU 6 Buttons IP Control Panel Program buttons to send RS232 commands to control projectors screens and other third party devices All Rights Reserved Version TF6P EU_2022V1 1 User Manual ...

Page 2: ...TF6P EU 6 Buttons IP Control Panel U T E electronic GmbH Co KG www ute de ...

Page 3: ...marks mentioned in this manual are acknowledged as the properties of the trademark owner No part of this publication may be copied or reproduced without the prior written consent FCC Statement This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications It has been teste...

Page 4: ...TF6P EU 6 Buttons IP Control Panel U T E electronic GmbH Co KG www ute de ...

Page 5: ...e the unit to rain moisture or install this product near water Do not put any heavy items on the extension cable in case of extrusion Do not remove the housing of the device as opening or removing housing may expose you to dangerous voltage or other hazards Install the device in a place with fine ventilation to avoid damage caused by overheat Keep the module away from liquids Spillage into the hou...

Page 6: ...on Procedure 4 3 3 System Diagram TF6P EU 5 4 GUI Control 6 4 1 Log in 6 4 2 Home Tab 7 4 3 Configuration Tab 8 4 3 1 Knob Menu 8 4 3 2 Button Menu 9 4 3 3 Add Button Event 10 4 3 3 1 Add TCP IP Event 10 4 3 3 2 ADD RS232 Event 10 4 3 3 3 Add IR Event 11 4 3 3 4 Add Relay Event 11 4 3 3 5 Add LED Event 12 4 3 3 6 Add Delay Event 12 4 4 Network Tab 13 4 5 Setting Tab 14 4 6 Upgrade Tab 15 5 Specifi...

Page 7: ...er projectors screens etc Use the device for presentations in showrooms classrooms and boardrooms 1 2 Features Six customizable control buttons One volume control knob Support IR RS232 and TCP IP control Can be controlled and configured via GUI Can be powered by PoE 1 3 Package List 1 x TF6P EU Programmable 6 Buttons Wallplate IP Control Panel 6 x Button caps 1 x 5 Pin Pluggable terminal block 2 x...

Page 8: ...nates green when power on 2 Volume Knob Black volume knob high quality knob with high damping feel and stable structure about 12 13mm in diameter 3 Button 6 crystal and luminescent programmable buttons Each button can be programed with the Control Panel Software Each label within a button can be easily changed Simply select the label you need and change it as shown below ...

Page 9: ...ory defaults and then the LED will light up while the resetting is successful 7 IR Sensor Receives and learns the IR code to build the IR database 8 PWR 12V Connects with 12V DC power adaptor 9 RELAY Two groups of Relay Control share a common switch interface default ON 10 IR Two sets of IR OUT share a ground port 5V standard connect to the infrared emitting rod 11 RS232 2 RS232 ports Connect the ...

Page 10: ...n a clean environment with proper temperature and humidity All of the power switches plugs sockets and power cords should be insulated and safe 3 2 Connection Procedure Step1 Connect the TF6P EU to the LAN port of Wireless Router or control device such as PC to TCP IP port Step2 Connect the third party devices such as Matrix Switcher Scaler Switcher or Projector that need to be controlled to RS232...

Page 11: ... Diagram TF6P EU The following figure shows a typical application that can be realized with 6 Buttons IP Control Panel TF6P EU Figure 3 1 Connection and System Diagram Note Pictures shown in this manual are for reference only different model and specifications are subject to real product ...

Page 12: ...ct with TF6P EU through graphical icons and visual indicators 4 1 Log in The TF6P EU is controlled by TCP IP The default IP settings are IP Address 192 168 0 178 Subnet Mask 255 255 255 0 Type 192 168 0 178 in your browser it will enter the log in interface shown as below Username admin Password admin Type the username and password and then click the login to enter the GUI setting ...

Page 13: ...IP Control Panel U T E electronic GmbH Co KG 7 www ute de 4 2 Home Tab Click the volume icon to adjust the volume or click the knob icon to implement the corresponding event Mouse operation click the corresponding button ...

Page 14: ... GmbH Co KG 8 www ute de 4 3 Configuration Tab 4 3 1 Knob Menu Knob Button Choose the knob or button to enter the event setting page Start up Click to enter the starts up event setting page Set the Knob events Turn Left Press Down Setting or Turn Right ...

Page 15: ...c GmbH Co KG 9 www ute de 4 3 2 Button Menu Click the Button 1 to set the button 1 event click Add Event and then set the Event and the corresponding settings One button can set multiple command events such as TCP IP RS232 IR RELAY Delay and LED status ...

Page 16: ...lectronic GmbH Co KG 10 www ute de 4 3 3 Add Button Event 4 3 3 1 Add TCP IP Event Set the TCP IP event such as IP Port Format End Char for ASCII and Data 4 3 3 2 ADD RS232 Event Set the RS232 event and then click save button to finish setting ...

Page 17: ...4 3 3 3 Add IR Event In IR event user can import or export the IR command Set the Event Name Port Code or Custom and IR Code for the event Click Save button to finish setting 4 3 3 4 Add Relay Event Set the Event Name Port and the Action Mode Click Save button to finish setting ...

Page 18: ...o KG 12 www ute de 4 3 3 5 Add LED Event Set the Event Name Button Select Status and LED Color Click the Save button to finish setting 4 3 3 6 Add Delay Event Set the delay event to trigger the event after how long to press Click Save button to finish setting ...

Page 19: ...TF6P EU 6 Buttons IP Control Panel U T E electronic GmbH Co KG 13 www ute de 4 4 Network Tab Select dynamic or static IP mode Under static mode then IP Address Subnet Mask and Gateway can be reset ...

Page 20: ...G 14 www ute de 4 5 Setting Tab Credentials setting the user name and new password and then click confirm button to perform the modification Update Profile Import or export the setting file to implement the system configuration Factory Default Click Factory reset ...

Page 21: ... IP Control Panel U T E electronic GmbH Co KG 15 www ute de 4 6 Upgrade Tab Firmware Upgrade click the browse to choose the upgrade file the file need to be renamed as WP6P app and then click upgrade to execute upgrade ...

Page 22: ...2 x Relay Output Connector 2 x 3 Pin Pluggable terminal blocks 2 x 2 Pin Pluggable terminal blocks Baud Rate 9600 baud supports 9600 19200 38400 57600 115200 Power Consumption 2 5W Max Operation Temperature 0 40 Storage Temperature 10 55 Relative Humidity 10 90 Power Supply Input 12VDC PoE Net Weight 195g Dimensions W H D 86mm x 86mm x 50 5mm ...

Page 23: ...TF6P EU 6 Buttons IP Control Panel U T E electronic GmbH Co KG 17 www ute de 6 Panel Drawing Figure 6 1 Panel Drawing TF6P EU ...

Page 24: ...service provided for the products or any other items sold by authorized dealer only 3 What the warranty does not cover Warranty expiration Factory applied serial number has been altered or removed from the product Damage deterioration or malfunction caused by Normal wear and tear Use of supplies or parts not meeting our specifications No certificate or invoice as the proof of warranty The product ...

Page 25: ...to our after sales department or make a call please inform us the following information about your cases Product version and name Detailed failure situations The formation of the cases Remarks For any questions or problems please try to get help from your local dealer or our customer support info ute de ...

Page 26: ...TF6P EU 6 Buttons IP Control Panel U T E electronic GmbH Co KG www ute de ...

Page 27: ...TF6P EU 6 Buttons IP Control Panel U T E electronic GmbH Co KG www ute de ...

Page 28: ...U T E electronic GmbH Co KG Tel 49 0 2302 28283 0 Fax 49 0 2302 28283 10 Email info ute de Website www ute de ...