Fire System Monitoring Panels
Chubb Fire & Security Pty Ltd
Technical Manual
Page 6 of 22
1: FSM-S and FSM-ES panels
Introduction
The FSM-S (Standard model) and FSM-ES (Engine shutdown model) panels comprise a combination
indicator panel and user interface. The indicator panel provides visual and audible indication of system
status, alarms, and faults and the user interface incorporates a RESET, TEST (LED’s and Buzzer), DIM
(LED Brightness) and ACK (Acknowledge/Silence Buzzer) features. The interface of the FSM-ES model also
allows manual extension of the equipment shutdown delay.
To minimize the effects of electromagnetic emissions from high energy sources the input cables should
NOT
be run parallel, or in close proximity to any cables or equipment that may produce high RF (radio frequency)
energy, e.g. cabling for RF transceiver antennas, inverters, motors etc.
Figure 1 – FSM-ES Typical installation
All wiring and electrical connections must be installed in accordance with the customer’s requirements and/or
the equipment manufactures specifications. Power supply and equipment shutdown connections should
either be completed by the Customer/OEM or an approved contractor.
Standard features
1.
IP 65 rated enclosure and Deutsch connector on
300mm fly lead
2.
8 to 35 volts operating range (nominal 12 or 24
volts)
3.
Cylinder low pressure switch 2 pole
4.
Buzzer output 85 dBA at 1 metre
5.
Discharge pressure switch 2 pole
6.
Ultrabrite mini LED's
7.
2 Amp Equipment shutdown relay 3 pole output
(FSM-ES model only)
8.
Variable engine shutdown delay periods 0, 15,
30 and 60 seconds (FSM-ES model only)
9.
AS 5062 compliant features
10.
Manual dim push button
11.