CASTELLANO
ENGLISH
Pág. 4
Manual de instrucciones 50200XXX Revisión 4 de Marzo-05
3. ESPECIFICACIONES TÉCNICAS
La serie 200 de estereomicroscopios Ura Technic está compuesta por las siguientes ver-
siones con características:
Iluminación
Cabezal
Modelo
Objetivos
Ocular
Inc.
Trans. Recto Incl. 45º Girat. 360 º
210
2X
WF 10X
Si
No
Si
No
No
214/1
2X
WF 10X
Si
No
Si
No
No
214/2
2X
WF 10X
Si
Si
Si
No
No
216/1
2X
WF 10X
Si
No
No
Si
No
216/2
2X
WF 10X
Si
Si
No
Si
No
218/1
2X, 4X
WF 10X
Si
No
No
Si
No
218/2
2X, 4X
WF 10X
Si
Si
No
Si
No
219/1
2X, 4X
WF 10X
Si
No
No
Si
Si
219/2
2X, 4X
WF 10X
Si
Si
No
Si
Si
220
2X, 4X
WF 10X
Si
Si
No
Si
Si
201
2X
WF 10X
Si
No
No
Si
No
Otras características (según modelo)
- Base: metálica, muy estable, contiene en su interior el transformador para la iluminación.
- Par de pinzas: en la base, para sujetar la muestra.
- Cuerpo binocular: ajustable en altura sobre el soporte.
- Distancia interpupilar: ajustable 30º.
- Corrección dióptrica: ± 5 mm en un tubo ocular.
- Par de oculares: estándar (10x), con sistema de fijación.
- Sistema de enfoque: por piñón y cremallera, con parada de seguridad al final del reco-
rrido y regulación de tensión.
- Mandos de enfoque: bilaterales con dispositivo de control de fricción.
- Platina: de vidrio esmerilado de 95 mm de diámetro (Según modelo).
- Par de anteojeras.
- Selector de intensidad de la luz: según modelo.
- Interruptor de luz: selector de luz incidente, transmitida o ambas a la vez, según modelo.
- Lámpara halógena 12 V 10W.
Especificaciones ópticas
- Tabla 1, modelos 214 y 216 -
OCULARES
5X
10X
15X
20X
OBJETIVOS
Aum. Ø Aum. Ø Aum. Ø Aum. Ø
Distancia
campo campo
campo
campo
Trabajo
1X
5X
22 mm
10X
20 mm
15X
15 mm
20X
10 mm
57 mm
2X
10X
12 mm
20X
10 mm
30X
7,5 mm
40X
6,5 mm
80 mm
3X
15X 8 mm
30X
6,7 mm
45X
5 mm
60X
4,3 mm
61 mm
4X
20X 6 mm
40X
5 mm
60X
3,7 mm
80X
3,2 mm
57 mm
6X
30X
4 mm
60X
3,3 mm
90X
2,5 mm
120X
1,8 mm
66 mm
Aum
F
Aumentos
Version 4 March-05
Instruction manual 50200XXX Page 17
Do not place the stereomicroscope near any warm supply (burners, blowlamps, etc),
nor expose it directly to the sun. Avoid vibrations, dust and dry environments.
During its functioning dangerous materials such as flammable or pathological substan-
ces must be out of the safety area.
When you are not using the stereomicroscope for a long period of time please make sure
it is unplugged in order to avoid possible accidents.
It is essential to have the equipment switched off and unplugged from the net
before
cleaning, checking components or replacing any piece (e.g. replacement of a fuse).
Never try to repair the stereomicroscope by yourself, since you will lose the warranty
and may provoke damages to the general operating system or the electrical installation,
as well as injuries to the people that usually handle the equipment (burns, hurts…).
Made under the European regulations for electrical security, electromagnetic compati-
bility and security on machines.
5. MAINTENANCE AND CLEANING
To get the best results and a higher duration of this equipment it is essential to follow
the processes of use.
Note:
All the processes of use mentioned below will not have any value unless you keep
a continued and careful maintenance.
Please follow the processes of use of this manual.
This manual should be available for all users of this equipment.
Always use original components and supplies. Other devices can be similar but they
can damage the equipment.
The stereomicroscope is supplied with a Schuko standard wire. It has to be plugged to
an earth connection and the socket should be handy and ready to unplug the equipment
in case of emergency.
Never try to repair the stereomicroscope by yourself, since you will lose the warranty
and may provoke damages to the general operating system or the electrical installation,
as well as injuries to the people that usually handle the equipment (burns, hurts…) or
damages in nearby equipments.
In the event of breakdown please contact your distributor to overhaul through Ura
Technic Technical Assistance Department.
If the are lamps blown you should replace them by another original Ura Technic ones
of 12V10W, being careful not to touch them with the naked hands. Do not use any lamp
with higher power, as this could provoke overheating or any other malfunction.
Were it essential to replace the fuse (0,5A), you should change it as follows: unscrew the
protective lid (FUSE) that you will find at the rear part of the base, replace the fuse loca-
ting the new one at the same position and screw it again once you have finished.
Do please always use the plastic cover whenever the stereomicroscope is not being used
to avoid dust on the optical parts.
Please keep the original packaging so as to use it in transport, whenever you have to