![USX-MOUNT XTL018-1 Instruction Manual Download Page 11](http://html.mh-extra.com/html/usx-mount/xtl018-1/xtl018-1_instruction-manual_1064709011.webp)
3/8"
(10mm)
2.5"(64mm)
11
CAUTION: Avoid potential personal injury or property damage!
● Mount the wall plate assembly unit directly onto the concrete surface
● Minimum
solid concrete
thickness: 8 in. (203 mm)
1. Position the wall plate unit on the wall at your desired height. Level the wall plate and mark the hole
locations.
2. Drill four pilot holes using a 3/8 in. (10 mm) diameter masonry drill bit.
IMPORTANT: Pilot holes must be drilled to a depth of 2.5 in. (64 mm).
Mounting template
R
8"(203.2mm)
16"(406.4mm)
24"(609.6mm)
Wall
Wall