USR-W630 User Manual
Technical Support:
Jinan USR IOT Technology Limited
www.usriot.com
8
When work at TCP Server mode, it support up to 24 Client to connect
Support set baud rate, range: 300bps to 460800bps
Support set parameters on webpage
Support reload
The distance for transmission can be 210m
Ensure production quality
2.3. Electrical Parameters
Table 1 default parameters
Item
Index
Wireless parameters
Standard authentication
FCC/CE
Wireless standard
802.11 b/g/n
Frequency range
2.412GHz-2.48GHz
Transmitting power
802.11b: +20dBm(Max.)
802.11g: +18dBm(Max.)
802.11n: +15dBm(Max.)
User define
Receiving sensitivity
802.11b: -89dBm
802.11g: -81dBm
802.11n: -71dBm
Hardware parameters
Data interface
UART
:
300bps-460800bps
RS485(Surge prevention, lightning
protection,
over-current
protection)
Enternet:10Mbps/100Mbps
Working voltage
DC5-36V
Working temperature
-20
℃
-70
℃
Storage temperature
-40
℃
-125
℃
Size
103*105*25mm
(
L*W*H
)
Software parameters
Wireless network type
STA/AP mode
Security mechanism
WPA-PSK/WPA2-PSK
Encryption type
TKIP/AES
Working mode
Transparent transmission mode/
Serial port command mode/
Httpd Client mode/
Modbus mode
Setting command
AT+command
Network protocol
TCP/UDP/ARP/ICMP/DHCP/DNS/HT
TP
Max number of TCP connect
24
User setting
Web AT commands