USR IOT USR-K7 User Manual Download Page 4

 

                                 

Super Port User Guide                                          www.usriot.com 

Jinan USR IOT Technology Co., Ltd                                                                                    [email protected]                                                     

Page4

/

34

 

1.2.

 

Basic parameters 

 

category 

parameters 

value 

 

 

Hardware 

parameters 

Work volt 

DC 3.0

3.6 V

,(

the best is3.3V) 

Work current 

[email protected] 

Net port 
specification 

RJ45

10/100Mbps

adopted to both cross and direct 

connection   

Packaging from 

Pin type packaging 

 

Serial port baud 
rate 

600

1M

bps

 

 
 
 
 
 
 
 
 
 

Software 

parameters 

Network protocol 

IP

TCP

UDP

DHCP

DNS

HTTP

ARP

ICMP

Web 

socket 

IP access way 

Static IP

DHCP 

Domain name 
resolution 

Support   

User configure 

Software configure, webpage configure,                   
AT commend configure 

Single transparent 
transmission 

TCP Server/TCP Client/UDP Server/UDP Client 

Modbus 

Modbus gateway: Modbus RTU to TCP, Modbus Polling 

Webpage to serial 
port 

  Web-Socket: web-page to serial port 

Httpd Client 

Support   

Class RFC2217 

Support   

Customize 
webpage 

Support   

Web caching 

Sent

16Kbyte

Sent

16Kbyte

 

Serial port caching 

Sent

2Kbyte

Sent

2Kbyte

 

Average 
transmission delay 

In LAN<10ms 

Software kit 

Virtual.com, serial port, USR-Cloud, parameter configure 

 
 

 
 
 

Others   

Identification   

CE

FCC

ROHS ( Will be got in June) 

Level class 

1.5KV EMC 

size 

35.0x19.39x18.25 mm(L*W*H) 

Work tempt 

-40

85c 

Store tempt 

-40

105c 

Work humidity 

5%

95% RH(no condensation) 

Store humidity 

5%

95% RH(no condensation) 

Diagram 1-1    Electrical parameters 

 

Summary of Contents for USR-K7

Page 1: ...Super Port User Guide www usriot com Jinan USR IOT Technology Co Ltd Sales usriot com Page1 34 Serial to Ethernet converter Super Port USR K7 File version V1 0 0...

Page 2: ...transmission text 9 3 Work mode 10 Diagram 3 2 work mode AT commend 11 3 1 UDP mode 11 3 2 TCP Client 12 3 3 UDP Server mode 13 3 4 TCP Server mode 15 3 5 Httpd Client mode 16 4 Hardware 18 4 1 Hardw...

Page 3: ...sy webcam networks and complex network environments such as fiber optic to Ethernet 1 2 Features 1 New Cortex M4 kernel industrial working temperature range 40 85 elaborate optimization TCPIP protocol...

Page 4: ...gure webpage configure AT commend configure Single transparent transmission TCP Server TCP Client UDP Server UDP Client Modbus Modbus gateway Modbus RTU to TCP Modbus Polling Webpage to serial port We...

Page 5: ...40 85 C Store temperature 40 85 C 5 95 RH Buffer of comm port 2K byte Buffer of Network 16K byte 1 4 Electrical characteristics All the data is get at temperature 25C network cable plug in max data t...

Page 6: ...192 168 0 201 must be a format of 192 168 0 xxx net mask 255 255 255 0 Connect development board s RS232 and PC s comm port together with a standard male female extend cable default no cross over cabl...

Page 7: ...92 168 0 24 range User name and password is admin User name and password are both admin this can be modified after login into the system Default user name admin Default password admin After you login...

Page 8: ...efault settings The right side is the network side protocol sets as TCP Client server IP sets as 192 168 0 7 port 23 By default USR K7 works as TCP Server port 23 This illustration shows the 10 ms two...

Page 9: ...6 Default parameters 2 4 Data transmission text After above steps you can do bi communication between serial port and Ethernet Step are as follows 1 Open the USR TCP232 Test exe connect the hardware 2...

Page 10: ...7 Default parameters text 3 Work mode There are 5 work modes for K7 including UDP Client TCP Client UDP Server TCP Server Httpd Client You can configure it by webpage and setting software Detail are...

Page 11: ...rom this udp port send it to serial port otherwise when data is received from serial port send it to ethernet The assist software can be download from link below http www usriot com Download 199 html...

Page 12: ...This mode have a function that identify connection exceptions actively After connected there will be about 15s internal to sent KeepAlive If there is an abnormal interruption of the connection etc it...

Page 13: ...Super Port User Guide www usriot com Jinan USR IOT Technology Co Ltd Sales usriot com Page13 34 Use USR TCP232 Test Diagram 3 6 TCP Client communication test 3 3 UDP Server mode...

Page 14: ...est communication IP and port number 2 This pattern is usually used for data transmission scenarios where multiple network devices need to communicate with the module and do not want to use TCP due to...

Page 15: ...ver mode 1 In TCP server mode module listens to the local port accepts connection requests and established connection for data communication When the module port receive the data it will sent data to...

Page 16: ...k as a TCP server its max link number is 8 later expanded to 32 TCP Server mode have 2 parameters max link number and link type 1 max link number 1 8 Diagram 3 11 Webpage configuration 3 5 Httpd Clien...

Page 17: ...r web page developer We establish one web server page add this php echo _GET data Means we can GET data from HTTP client s request Open this URL test usr cn 1 php data 12345 the web page is downbelow...

Page 18: ...type in a string such as 12345 then send via comm port to USR K7 and see the response from test usr cn In the response all the data returned but the http header from server will be returned too the us...

Page 19: ...echanical dimesion 33 02 x 19 01 x 19 15 mm include the Shrapnel 3 3V power input 1 UART TTL 3 3V support hardware flow control RTS CTS 4 2 Pin definition USR K7 module has 16 external pins two of whi...

Page 20: ...send controlling pin high level to send 6 Reload Module can restore the factory settings in the case of module power off or reset pull down Reload then power on keep Reload 5S pull down after more th...

Page 21: ...Super Port User Guide www usriot com Jinan USR IOT Technology Co Ltd Sales usriot com Page21 34 4 3 Size Diagram 4 4 inches...

Page 22: ...ED_LINK together Connect RXD TXD with user s MCU Leave the unused pin to a float state 4 5 LED Diagram 4 6 LED definition 4 6 RJ45 interface Ethernet port of module is 10 M 100 M adaptive support AUTO...

Page 23: ...ode In order to ensure the normal use of the setup software the following steps are required 1 When using setup software to set parameters it is necessary to ensure that K7 and the computer setting so...

Page 24: ...ult user name admin password admin software default user name and password is admin so the default parameter Settings and there won t pop up Windows Diagram 5 2 software setup parameters enter passwor...

Page 25: ...Super Port User Guide www usriot com Jinan USR IOT Technology Co Ltd Sales usriot com Page25 34 Diagram 5 3software setup parameters Full show...

Page 26: ...User name the user name of K7 and the authentication code can prevent other users in the same LAN from modifying K7 parameters Password same as user name Device name can be modified User MAC static IP...

Page 27: ...r at which K7 initiates the connection is recommended to be set to 0 when K7 is the TCP Client that is the connection is initiated with a random port number TCP Server none modbus TCP use it when you...

Page 28: ...computer only one IP address the computer and the module is best connected directly prohibit the computer through WiFi to upgrade the module firmware Diagram 5 6 Software setup parameters upgrade 6 Sp...

Page 29: ...s TCP by setup program Note There are two potions in this place Modbus TCP None which showed we are using a standard Transparent mode no protocol conversion Modbus TCP means we use protocol conversion...

Page 30: ...e firmware of 3010 and later supports the heartbeat package function which can send heartbeat packets to both the serial port and the network Diagram 6 4 Serial port network heartbeat package 6 3 Regi...

Page 31: ...inan USR IOT Technology Co Ltd Sales usriot com Page31 34 Set up a connection to send a registration package is mainly used to connect to the server which need to register Diagram 6 6 Registration 6 4...

Page 32: ...ustomize webpage and with WebSocket function they can customize their own communication protocol for transmission which is more convenient If you need to customize webpage please contact with USR Diag...

Page 33: ...34 7 Contact us Company Jinan USR IOT Technology Co Ltd Address Floor 11 Building1 No 1166 Xinluo Street Gaoxin Distric Jinan Shandong 250101 China Tel 86 531 55507297 86 531 88826739 803 Web http ww...

Page 34: ...Super Port User Guide www usriot com Jinan USR IOT Technology Co Ltd Sales usriot com Page34 34 8 Modified history vision Modified instruction Time V1 0 0 first 2019 05 07...

Reviews: