Super Port User Guide www.usriot.com
Jinan USR IOT Technology Co., Ltd [email protected]
Page27
/
34
Diagram 5-5 Software setup parameters - port configuration
① baud rate: it can be standard baud rate or modified baud rate.
② parity/data/stop: serial port parameters
③ Flow control:None/RS485/Hardware, choose the hardware to use hardware flow control.
None/RS485 means no flow control.
④ work mode: TCP Server /TCP Client/ Httpd Client/UDP Client/UDP Server
⑤ remote IP: the IP connected to K7 when it work as client.
(
TCP Client/ Httpd Client/UDP
Client
)
⑥ remote port: the port number at which K7 initiates the connection is recommended to be set
to 0 when K7 is the TCP Client, that is, the connection is initiated with a random port number
⑦ TCP Server
:
none
⑧ modbus TCP
:
use it when you use th e function Modbus TCP to Modbus RTU
⑨ time of serial port : please refer to software of k7
⑩
Synchronous baud rate: it is used when the serial port parameters need to be changed during
transmission, with the use of virtual serial port software, or refer to the software design manual of
K7.
4. Firmware upgrade
The customer can use setup software to upgrade firmware
If the module needs to upgrade to a higher version of the firmware, the user can consult the sales
to upgrade the firmware, after getting the updated firmware, click the device, firmware upgrade,