background image

EN

11

Identification

How to set ID

Set the unit

Note

- This function is useful for public toilets, when more than one unit of this product is installed.

- To prevent interference among units, main unit and remote control should be set with the same ID.

- If there is only one USPA device with remote control in the bathroom, there is no need to set an ID.

- Initial ID of remote control and main unit is “0”. There are 16 ID codes available (00~15).

- After assigning the ID to the remote control, unplug the unit and the plug it back in.

- Press the “Power|Bidet” button on the left side (see picture aside) to turn off the unit.

- Press the “Power|Bidet” button again without releasing (the unit should turn back on at this point).

- While holding the “Power|Bidet” button down, push “Stop” on the remote control for 2 seconds.

- If the IDs of the remote control and the main unit are different, the remote can’t work properly. Make sure that remote control and 

main unit are set with the same ID.

- The ID will be memorized even when the device is unplugged or when the batteries of the remote control are replaced.

[REMOTE CONTROL]
- Press “High”               for 3 seconds and the ID will show up in the display.

- Press “High”                or “Low”                 until your ID appears in the display.

- Press “Stop” to save the ID.

10

11

10

11

Summary of Contents for UB-6635R

Page 1: ...in an easily accessible location Please register warranty for proper service UB 6635R 6635RS 6635RU Personal Hygiene Appliance Operating Instruction Manual Thank you for purchasing this USPA product Y...

Page 2: ...tem for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial w...

Page 3: ...maged cord or plug if it is not working properly if it has been dropped damaged or dropped into water 4 Install this appliance properly according to this manual 5 Only authorized people can install or...

Page 4: ...freeze during storage in winter In that case warm the unit in the room before installation 7 The termal protector in the water tank my sometimes trip during storage or transportation in warm weather...

Page 5: ...Mounting bolt 2pcs Water hose 120 cm Elbow connector 2pcs 1 2 T valve 1 2 T valve 3 8 Extra foot seat 2pcs Bolt guide 2pcs Remote control Battery AAA 3pcs Screw 2pcs Plastic anchor 2pcs Mounting plate...

Page 6: ...ce Prohibited Do not throw any firearms Do not handle with wet hands Do not disassemble Ground connection Required step Doing so may result in a short circuit electric shock or fire Doing so may resul...

Page 7: ...nd unplug properly Doing so may result in fire or damage Doing so may result in electric shock due to high voltage inside Doing so may result in fire or electric shock Unplug right away Not doing so m...

Page 8: ...m air outlet Do not force the lid to close Do not sit or lean against the lid or control panel Unplug while there is a thunder or lightening Unplug while not using over extended period of time Doing s...

Page 9: ...ay result in a low grade burn if sitting on the heated seat for a long time If injured in a low grade burn see a doctor immediately If high temperature is set up it may result in burnduetonotrecognizi...

Page 10: ...this button to activate feminine wash The function will stop automatically after 1 minute Press this button again to activate oscillation The nozzle moves automatically back and forth to widen cleans...

Page 11: ...consecutively 1 minute followed by Drying function 3 minutes Press Bidet and Auto in sequence if the Auto function is desired in conjunction with the Bidet function Nozzle position can be adjust 5 lev...

Page 12: ...Bidet Left side USER 1 USER 1 USER 2 USER 2 CLEANSING NOZZLE POSITION WATER PRESSURE BIDET NOZZLE POSITION WATER PRESSURE To recall previously memorized settings press User 1 or User 2 during Cleansin...

Page 13: ...Press the Power Bidet button on the left side see picture aside to turn off the unit Press the Power Bidet button again without releasing the unit should turn back on at this point While holding the P...

Page 14: ...ng of the nozzles Press Stop button while cleaning to retract the nozzles feminine feminine posterior posterior Water tank Water hose Shutoff valve Strainer 1 2 3 8 T valve Toilet cleanser Thinner Ben...

Page 15: ...plug and drain the water from the water tank and pipes thoroughly Screw the drain bolt and install the appliance Close the shutoff valve Uphold the appliance and thoroughly drain the water by unscrewi...

Page 16: ...se dimensional requirements This appliance is equipped with occupied sensor Unit will not work unless seat is occupied Occupied sensor Seat How to attach and detach the unit Caution Remove the existin...

Page 17: ...hose from the T valve to the main appliance Open the shutoff valve by turning counter clockwise Check for any water leaking or dripping Trial operation 1 Preparation Plug the power cord into the outl...

Page 18: ...ion Water pressure Water capacity Heat capacity Heater capacity Heater capacity Safety feature Safety feature Safety feature Spray for cleansing Spray for bidet Spray temperature Air temperature Seat...

Page 19: ...r or for labor or other costs due to installation or removal or cost or repairs by others or for any other expense not specifically stated above Except to the extent prohibited by appliance law any im...

Page 20: ...MEMO...

Page 21: ...MEMO...

Page 22: ...RO GANGNAM GU SEOUL KOREA T 82 2 3218 9343 F 82 2 512 5101 www isdongseo co kr IS DONGSEO CO LTD USPA EUROPE S R L CORSO DELLA VITTORIA 14 28100 NOVARA ITALY T 39 0321 030449 F 39 0321 031648 www uspa...