LSS−100P Installation & Operation Manual
v160817
23
Command
Response
Description
lss100.sys.comments
Conference Room
Returns the auditorium
comments entered on the
configuration page.
lss100.sys.ftl
118.332596
Returns the measured
luminance in foot-Lamberts
lss100.sys.spl
83.239520
Returns the measured sound
pressure level in dBc
lss100.sys.temperature
29.2\t84.
Returns the internal
temperature in degrees C and
degrees F (separated by tab).
lss100.sys.theater_name
USL San Luis Obispo Returns the theater name
entered on the configuration
page.
lss100.sys.theater_number
1
Returns the theater number
entered on the configuration
page.
lss100.sys.ver
H\t130522\t120530 Returns the circuit board
version, the firmware version,
and the bootloader versions,
separated by tab.
lss100.sys.xy
0.314743\t0.353419 Returns the chromaticity as x
tab y.
lss100.sys.capture_spl|SPL Center Low|81.2|83.2
83.239520
Instructs the LSS-100P to
capture the current SPL to its
log. The parameters are
description, min, and max.
Returns the current SPL in dBc.
lss100.sys.capture_fl|Luminance|13|15
14.1234
Instructs the LSS-100P to
capture the luminance
(measured in fL) to its log. The
parameters are description, min,
and max.
lss100.sys.capture_cdm2|Luminance|47|49
48.4321
Instructs the LSS-100P to
capture the luminance
(measured in cd/m
2
) to its log.
The parameters are description,
min, and max.
lss100.sys.capture_cct|Color Temperature|6100|6300
6262
Instructs the LSS-100P to
capture the correlated color
temperature in Kelvin to its log.
The parameters are description,
min, and max
lss100.sys.capture_temperature_c|Temperature|20|40 25
Instructs the LSS-100P to
capture its internal temperature
in Celcius to its log. The
parameters are description, min,
and max.