In general, install combination Smoke, CO and Gas Alarms:

WHERE YOU CAN HEAR THE ALARM FROM ALL SLEEPING AREAS.

In or near bedrooms and living areas or wherever you suspect a smoke, natural gas or CO
exposure is likely.

On each level of a multilevel home.

IMPORTANT!

Installation in an improper location can affect the sensitive electronic components in this alarm.
Please review WHERE THIS ALARM SHOULD NOT BE INSTALLED (see Page 6).

Not suitable for installation in hazardous locations as defined in the Canadian National Electrical
Code. This alarm will detect natural gas primarily and carbon monoxide secondarily. Natural gas
events will always take precedence over carbon monoxide events. The word "gas" will be used to
specifically refer to natural gas.

When on AC power, this alarm is designed to act as a continuous monitor. It is not designed for use
as a short-term testing device to perform a quick check for the presence of CO or gas.

BASIC SAFETY INFORMATION

This combination Smoke, Carbon Monoxide and Natural Gas alarm has separate alarms. This
alarm is not designed to detect any other gas. Carbon monoxide and natural gas may be present
in other areas. The Smoke, CO and Natural Gas Alarm will only indicate the presence of CO or
natural gas which reaches the sensor.

NOTE: For your convenience, we provide separate labels for  the French-language product markings.
If you choose to utilize those markings, remove the label from the backing and apply it to the alarm.
Carefully align the label in the appropriate space and press firmly to ensure the label permanently
adheres to the alarm.

Do not paint  the alarm. Paint may clog the openings to the sensing chambers and prevent the
unit from operating properly.

Do not stand too close to the unit when the alarm is sounding. It is loud to wake you in an
emergency. Exposure to the horn at close range may harm your hearing.

Make sure the alarm is not receiving excessively noisy power. Examples of noisy power
could be major appliances on the same circuit, power from a generator or solar power, light
dimmer on the same circuit or mounted near fluorescent lighting. Excessively noisy power
may cause damage to your alarm.

Page 5

This alarm cannot be operated from power derived from a square wave, modified square wave or
modified sine wave inverter. These types of inverters are sometimes used to supply power in off-grid
installations, such as solar or wind derived power sources. These power sources may produce high
peak voltages which will damage the alarm.

Do not install this alarm into an electrical circuit controlled by a dimmer or switch or ground
fault circuit interrupter.

Summary of Contents for UNIVERSAL MDSCN103CN

Page 1: ...ld help protect you and your family PLEASE READ AND SAVE Table of Contents Page Alarm Limitations and Functions 2 What You Should Know About CO 3 What You Should Know About Natural Gas 3 Basic Safety...

Page 2: ...ETY HAZARDS LIKE SMOKING IN BED VIOLENT EXPLOSIONS ESCAPING GAS IMPROPER STORAGE OF FLAMMABLE MATERIALS OVERLOADED ELECTRICAL CIRCUITS CHILDREN PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR...

Page 3: ...ical problems may consider using warning devices which provide audible and visual warnings for carbon monoxide concentrations under 30 ppm IMPORTANT CONSIDERATIONS YOUR COMBINATION SMOKE CO AND NATURA...

Page 4: ...ceiling shall be located within 36 in 914 mm horizontally of the peak but not closer than 4 in 102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or combination alarms mounted on...

Page 5: ...e presence of CO or natural gas which reaches the sensor NOTE For your convenience we provide separate labels for the French language product markings If you choose to utilize those markings remove th...

Page 6: ...et 6m from the sources or combustion particles stove furnace water heater space heater if possible In areas where a 20 foot 6m distance is not possible in modular mobile or smaller homes for example i...

Page 7: ...is alarm to a 24 hour circuit may prevent it from providing constant protection IMPORTANT Do not subject this alarm to megger high voltage or high pot tests Remove the alarm s before high potting test...

Page 8: ...only present in models MDSCN111CN MSDCN103CN MICN109CN MICN102CN MCN108CN and MCN105CN therefore a natural gas alarm will NOT trigger the alarm of non natural gas sensing models within an interconnec...

Page 9: ...40 seconds to indicate proper operation IMPORTANT The battery backup is designed to provide short term emergency power to the Smoke CO and Gas Alarm Actual backup time depends on the strength freshnes...

Page 10: ...ted the alarm will sound 3 chirps approx every 20 seconds Reset the alarm If the unit does not reset replace the alarm END OF SERVICE LIFE ALARM When it is time to replace your alarm which is approxim...

Page 11: ...on the level of CO detected If CO levels drop below alarm levels the alarm will remain silent and return to normal operation If CO levels remain constant or increase this indicates a potentially dange...

Page 12: ...t to natural gas outside of a controlled labatory environment can produce an explosion and death NEVER use a gas range or an open flame of any kind to test this alarm You might accidentally damage or...

Page 13: ...of the home and not reach the alarm installed on a different level For example CO or gas in the basement may not reach an alarm on the second level near the bedrooms For this reason we recommend you...

Page 14: ...nsumer is exempt from any licensing or requirements Simultaneous operation of several fuel burning appliances competing for limited internal air Vent pipe connections vibrating loose from clothes drye...

Page 15: ...sleeping area within 6 4 m 21 ft of any door to a sleeping room the distance measured along a path of travel 3 On every level of a dwelling unit including basements 4 On every level of a residential...

Page 16: ...ectedGASalarmhassensed GAS causing all interconnected units to sound If hazard is identified take all precautions if an alarm sounds by calling an Emergency Service and getting out of the home 3 Beeps...

Page 17: ...approx every 20 seconds Off Off Condition Product End of Service Life Notification Recommendation Replacethealarmimmediately Theproduct end of service life notification can be temporarily silenced fo...

Page 18: ...ES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREAT...