THANK YOU for purchasing this 3-in-1 Smoke + Fire + Carbon Monoxide Smart Alarm. 
This tamper-proof alarm contains a 10 year permanent power sealed battery to provide 
continuous protection--even in the event of a power outage.  The sealed battery will last 
for approximately 10 years. This manual includes important information regarding where 
to install the alarm, how to operate, maintenance, testing and product features. It also 
includes tips and information which could help protect you and your family.

TABLE OF CONTENTS

Alarm Technology & Key Product Features

  . . . . . . . . . . . . . . . . . . . . . . . . . .2

Alarm Limitations and Functions

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Installation Instructions

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

 

Where This Alarm Should Be Installed   . . . . . . . . . . . . . . . . . . . . . . .3

 

Where This Alarm Should Not Be Installed  . . . . . . . . . . . . . . . . . . . .5

 

Mounting Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

 

Tamper Resistant (Alarm) Locking Feature  . . . . . . . . . . . . . . . . . . . .6

 

Wiring Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

 

Stand Alone Alarm Installations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

 

Interconnected Alarm Installations    . . . . . . . . . . . . . . . . . . . . . . . . . .8

 

Interconnection & Compatibility  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Industry & Agency Recommendations 

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Alarm Operation 

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

 

Normal Operation   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

 

Trouble Signal   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

 

Alarm Reset  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

 

Quick Find®  Alarm Origination  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

 

Silence Feature   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

 

Testing Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Alarm & Battery Deactivation 

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

What To Do If Alarm Sounds—Carbon Monoxide Detected

  . . . . . . . . . . . .13

 

What You Should Know about Carbon Monoxide . . . . . . . . . . . . . .13

 

Symptoms of CO  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

 

Required CO Alarm Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

 

Response to CO Alarm Sounding  . . . . . . . . . . . . . . . . . . . . . . . . . .14

 

Potential Sources of CO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

What To Do If Alarm Sounds—Smoke Detected

  . . . . . . . . . . . . . . . . . . . . . .15

 

How Can I Protect My Family from Fire   . . . . . . . . . . . . . . . . . . . . .15

 

Develop An Escape Plan  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

Quick Reference Guide

 

Troubleshooting Information   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Warranty 

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

 

Alarm Returns   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

 

Repairs and Service   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

 

Regular Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

Summary of Contents for MPC122S

Page 1: ...ere This Alarm Should Not Be Installed 5 Mounting Instructions 6 Tamper Resistant Alarm Locking Feature 6 Wiring Instructions 7 Stand Alone Alarm Installations 7 Interconnected Alarm Installations 8 I...

Page 2: ...a safer greener alternative Quick Find Alarm Origination Feature easily identifies first alarm to sound in an intercon nected system ALARM LIMITATIONS AND FUNCTIONS IMPORTANT ALARMS WILL NOT WORK WITH...

Page 3: ...e who may not be awakened by the alarm sound or to those who may be incapable of safely evacuating the area unassisted ALARMS ARE NOT FOOLPROOF Test alarms weekly to ensure continued protection ALARMS...

Page 4: ...ide wall with the top edge of the smoke alarm a maximum of 6 15 2cm below the ceiling wall intersections See Diagram A Existing Homes The NFPA requires smoke alarms or combination alarms on every leve...

Page 5: ...allation in hazardous locations as defined in the National Elec trical Code To avoid causing damage to this alarm to provide maximum protection and to prevent unnecessary alarms DO NOT LOCATE THIS ALA...

Page 6: ...tions in or unconventional vent pipe designs which can amplify the above situations These placement recommendations are intended to keep alarms at a reasonable distance from a fuel burning source and...

Page 7: ...will damage the alarm Installation of this alarm must conform to the electrical codes in your area Article 760 of the National Electrical Code NFPA 72 101 SBC SBCCI UBC ICBO NBC BOCA OTFDC CABO and an...

Page 8: ...multiple alarms INTERCONNECTED ALARMS INSTALLATION The wiring to be used shall be in accordance with the provisions of Articles 210 and 300 3 B of the National Electrical Code ANSI NFPA 70 NFPA 72 and...

Page 9: ...f the dwelling When alarms are interconnected all alarms will sound when one alarm first sounds To prevent damage do not connect this alarm to any other type of alarm or auxiliary device Connecting in...

Page 10: ...tectors Model 501 A or 501 A Bat Aerosol Generator Manufactured by Gemini Scientific Corp 1122 B Aster Ave Sunnyvale CA 94086 The Equivalent UL 268 Light obscuration ft as measured by this instrument...

Page 11: ...system after all the alarms have stopped sounding 1 Press and release the test silence button on any interconnected alarm After releasing the button the test sequence will sound on all the interconnec...

Page 12: ...alarm You might accidentally damage or set fire to the alarm or to your home CAUTION Continuous exposure to the high sound level of this alarm over an extended period of time may cause hearing loss Du...

Page 13: ...D KNOW ABOUT CO Carbon monoxide CO is an insidious poison It is a colorless odorless tasteless gas It is a cumulative poison Even low levels of CO have been shown to cause brain and other vital organ...

Page 14: ...ur ers instructions or contact the manufacturer s directly for more information about CO safety and this equipment Make sure that motor vehicles are not and have not been operating in an attached gara...

Page 15: ...Check the color of the flame on the burner and pilot lights to ensure they are burning properly They should be blue If the flame is orange or yellow it is a sign the fuel is not burning completely and...

Page 16: ...ian for assistance Test the alarm following installation and weekly thereafter The built in test switch accurately tests the alarm operation as required byANSI UL217 and UL2034 Standards for Safety If...

Page 17: ...utton for 10 15 seconds and then release This will clear the alarm origination and latching LED Be sure to RESET alarms after every alarm event QUICK FIND Alarm Origination Location Feature The QUICK...

Page 18: ...warranty on this product created by state law shall extend beyond the term of this warranty unless such law otherwise provides USI specifically disclaims any liability and shall not be liable for any...