INSTALLATION

 

NOTE:  

DO NOT discard  

the carton or other packing 

materials until you have 

inspected the appliance for  

hidden damage and tested it  

for proper operation.  Refer to: 

SHIPPING DAMAGE CLAIM 

PROCEDURE

 on the inside of this 

manual. 

WARNING:

 

RISK OF PERSONAL INJURY 

Installation procedures must be  

performed by a qualified technician 

with full knowledge of all applicable 

electrical and plumbing codes.   

Failure can result in personal injury 

and property damage. 

IMPORTANT: 

Unit must remain in an upright 

position during installation to  

prevent damage to the  

refrigeration system. 

IMPORTANT: 

Refrigeration system is air-cooled. 

Recommended louvered grills or 

equivalent openings front and rear, 

each with a minimum size of twice 

the surface area of the condenser, 

to provide adequate air circulation. 

IMPORTANT: 

Access is required for the operation 

of the drain valve and for  

maintenance of the refrigeration unit. 

Provide adequate access to the drain  

valve and refrigeration unit. 

IMPORTANT: 

Unit flange must be sealed to the  

countertop.  Damage caused by leaks 

due to improper installation is NOT  

covered by warranty. 

UNPACKING & INSPECTION 

Carefully remove the appliance from the carton.  Remove all 

protective plastic film, packing materials and accessories from 

the appliance before connecting electrical power or otherwise 

performing any installation procedure. 
Carefully read all instructions in this manual and the 

Installation Instruction Sheet

 packed with the appliance before 

starting any installation. 
Read and understand all labels and diagrams attached to the 

appliance. 
Carefully account for all components and accessories before 

discarding packing materials.  Store all accessories in a 

convenient place for a later use. 

 

COMPONENTS 

2 ea.  PAN RAIL, SIDE 

2 ea.  PAN RAIL, END 

1-5 ea.  PAN RAILS, INTERMEDIATE (qty differs w/ unit)

1ea. 

BACKFLOW PREVENTER ASSEMBLY 

1ea. 

DRAIN VALVE 

1ea. 

DRAIN SCREEN 

PREPARATION 

Cutout dimensions for tank units and control panels are listed 

on the 

Installation Instructions

 provided with the unit. 

Countertop must be flat and level before the unit is installed.  

After cutout is made, add stiffeners or bottom braces to 

counter as required to support unit weight. 
Provide louvered grills and service access below control panel. 
After installation, apply a thin bead of food-grade silicone 

sealant around the flange to seal it to the counter. 
For installation in plastic counter tops, the counter material 

must be protected from the heat of the warmer in order to 

prevent discoloration and/or deterioration.  The installer 

should contact the manufacturer or distributor of the 

countertop material for specific installation instructions. 
Avoid storing flammable or combustible materials in, on or 

near the appliance. 

Summary of Contents for AFCHCP Series

Page 1: ...part of the appliance and is to be given to the OWNER or MANAGER of the restaurant or to the person responsible for TRAINING OPERATORS of this appliance Additional manuals are available from your USE...

Page 2: ...r fuse replacement are not covered by this warranty unless warranted conditions are the cause 2 All problems due to operation at voltages or phase other than specified on equipment nameplates are not...

Page 3: ...REQUIREMENT VOLTS KW 1 AMPS HP VOLTS 1 AMPS REFRIGERANT SYSTEM AFCHCP 2 240 208 60Hz 2 5 1 9 10 4 9 0 1 4 120 60Hz 3 9 R 134a capillary tube 3 wire L1 L2 N 8 AWG min 60 C AFCHCP 3 240 208 60Hz 4 0 3 0...

Page 4: ...FEATURES OPERATING CONTROLS...

Page 5: ...ustration and or adjustment procedures is intended for use by qualified technical personnel Any procedure which requires the use of tools must be performed by a qualified technician This manual is con...

Page 6: ...iance before connecting electrical power or otherwise performing any installation procedure Carefully read all instructions in this manual and the Installation Instruction Sheet packed with the applia...

Page 7: ...E While a backflow preventer is incorporated into the unit local codes may require an additional backflow preventer or vacuum breaker in the water inlet line 3 The unit must be installed on a water li...

Page 8: ...e HEAT indicator goes out the water in the tank is up to the set temperature 4 Install the pan rails a Side rails installed first For normal hot operation install the side rails on the upper pan rail...

Page 9: ...ater level probes 3 Rinse tank thoroughly with a vinegar and water solution to neutralize all detergent or cleanser residue 4 Pan rails and element cover may be washed in a sink or dishwasher Allow to...

Page 10: ...nd discard all lint and debris gathered from this operation IMPORTANT The fins of the condenser are delicate and easily damaged Use care to brush in a vertical motion to avoid damaging the coil fins 4...

Page 11: ...e only cloth or plastic pads Scrub only in a linear motion along the longest axis of the equipment 3 Use only non chloride and non ammonia cleansers a DO NOT use any cleanser listed as chlorinated b D...

Page 12: ...condensing unit is adjustable Temperature adjustment must be performed by a qualified refrigeration personnel only 3 Normal temperature setting would be 28 F AFC 1 7 thru AFC 6 7 The LCD Display provi...

Page 13: ...tting Factory differential is 3 F 4 Press the SET key again to access the Heating Cooling mode The LCD will display the current mode Either C1 for cooling or H1 for heating The control must be set to...

Page 14: ...t Authorized USECO Service Agency for repairs Tank won t fill Selector switch not set to HOT Set to HOT Max water level sensor dirty Clean water level sensors Drain valve open Be sure drain valve is c...

Page 15: ...ATA Please have this information available if calling for service RESTAURANT __________________________________ LOCATION _________________________ INSTALLATION DATE ____________________________ TECHNI...

Page 16: ...ace food directly into the tank IMPORTANT For NSF 7 operation use 12 x 20 x 4 deep pans and use the lower pan rail supports which are recessed 3 from tank top SHUT DOWN PROCEDURE 1 Turn SELECTOR SWITC...

Page 17: ...kages Pour contents packages into tank Stir to dissolve cleaner Cover tank 4 Allow solution to soak at least one hour or overnight for heavy scale buildup 5 After soak period turn control to OFF posit...

Reviews:

Related manuals for AFCHCP Series