INTRODUCTION
Thank you for purchasing this USECO
appliance.
Proper installation, professional operation and consistent maintenance of this appliance will
ensure that it gives you the very best performance and a long, economical service life.
This manual contains the information needed to properly install this appliance, and to use and
care for the appliance in a manner which will ensure its optimum performance.
ELECTRICAL & REFRIGERATION SPECIFICATIONS
MODEL
WARMER
REFRIGERATION
POWER SUPPLY
REQUIREMENT
VOLTS
KW
1
∅
AMPS HP
VOLTS
1
∅
AMPS REFRIGERANT
SYSTEM
AFCHCP-2
240/208
60Hz
2.5/1.9 10.4/9.0
1/4 120 60Hz
3.9
R-134a
capillary tube
3-wire: L1, L2, N
#8 AWG min. 60°C
AFCHCP-3
240/208
60Hz
4.0/3.0 16.7/14.4 1/3 120 60Hz
6.2
R-404a
capillary tube
3-wire: L1, L2, N
#8 AWG min. 60°C
AFCHCP-4
240/208
60Hz
5.0/3.8 20.8/18.1 1/2 120 60Hz
7
R-404a
capillary tube
3-wire: L1, L2, N
#8 AWG min. 60°C
AFCHCP-5
240/208
60Hz
8.0/6.0 33.3/28.9 3/4 120 60Hz
15.8
R-404a
TXV
3-wire: L1, L2, N
#8 AWG min. 60°C
AFCHCP-6
240/208
60Hz
8.0/6.0 33.3/28.9 3/4 120 60Hz
15.8
R-404a
TXV
3-wire: L1, L2, N
#8 AWG min. 60°C
NOTE: For equipment and cut-out dimensions, refer to the
installation instructions
provided with each unit.