Problem 

Possible Cause 

Solution 

Flow Meter is fluctuating 

1.  Pump is sucking air. 
2.  Restriction in the line. 
3.  Flow meter is not full of liquid 

1.   

 

Check and tighten all hose   

connections. 

1.  Check filter to see if gasket is 

missing or cracked. 

2.  Clean out filter and lines to 

check for any debris. 

3.  The meter will fluctuate if 

there is nothing pumping and 
there is some liquid left in the 
meter.  Drain out liquid. 

Flow meter won’t turn on 

1.  Improper power going to flow 

meter. 

2.  Loose connection. 

1.    Check incoming power to 

flow meter. 

2.    Check connections inside 

the control panel and inside 
the flow meter. 

Flow Meter is reading too low or 
too high. 

1.  Restriction in Flow Meter or 

in line. 

2.  Air in treatment.  This can 

cause the flow meter to read 
lower than calibrating it using 
a measuring cup. 

3.  Seed flow has changed. 

1.    Flush the flow meter with 

water or use compressed air 
and blow air backwards 
through the meter. 

2.    Check and tighten all hose   

connections. 

2.  Check filter to see if gasket is 

missing or cracked. 

3.  Recheck seed flow rate. 

Flow meter will not zero 

1.  Improper wiring 
2.  Wrong parameter             

programmed into flow meter 

1.    Check wiring schematic.     
2.    Check flow meter                   

parameters.  Call local 
dealer. 