USA Measurements US-PC-PH-15 User'S & Technical Manual Download Page 13

 

                                                          US-PC-PH & US-PC-PL 

  . 

11 

.

 

      display window shows “SETUP”, UNIT PRICE window shows "BLGt.Md" (backlight mode) and the TOTAL PRICE window   
      shows the backlight mode code x(x=1-3), use the numerical keys to input the backlight mode, and press ENTER key   
      for confirmation.   
      Press ON/OFF key to exit this mode and the scale will automatically reset. 

               

x=1 – back light is always off 

                      =2 – back light is always on 
                      =3 –Backlight On Request (backlight temporarily switches off after 15 seconds of inactivity, and 
reactivates with a key press or with an item placed on or removed off the pan) 

2.    When UNIT PRICE window shows “LCd.CST” (LCD contrast) and the TOTAL PRICE window shows the contrast level x   
      (x=1-9,default is 9). Use the numerical keys to input the contrast level, and press ENTER key for confirmation.   
      Press ON/OFF key to exit this mode and scale will automatically reset. 
 

6.

6.

6.

6.

 

Auto

Auto

Auto

Auto----off  time setting

off  time setting

off  time setting

off  time setting    

Under the normal weighing mode, press and hold ON/OFF and 2 key at the same time until the scale displays “SETUP” in 

WEIGHT window, “A.OFF.t” (auto off time) in UNIT PRICE window and auto-off time xx (xx=00

30, when 00 is used that 

means no auto off function) in TOTAL PRICE window. Use numerical keys to input the auto-off time and press Enter key 
for confirmation. Press ON/OFF key to exit this mode and the scale will automatically reset. 
 

 

7.

7.

7.

7.

 

Display A/D i

Display A/D i

Display A/D i

Display A/D inner code and working voltage

nner code and working voltage

nner code and working voltage

nner code and working voltage    

When in normal working mode, press ON/OFF and 3 key at the same time till the UNIT PRICE window shows “CodE 2” to 
enter this mode. Now WEIGHT window will show “UoL.x.x” (Voltage x.x V), this means the inner working voltage is x.x V. If 
the scale uses AC power adaptor, the voltage is the power adaptor voltage after regulating. If AC adaptor is not used, this 
around voltage is battery’s voltage. A/D internal code will be displayed in TOTAL PRICE.   
 
 

8.

8.

8.

8.

 

The details about RS232 commun

The details about RS232 commun

The details about RS232 commun

The details about RS232 communication

ication

ication

ication    

1.    Under the normal working mode, press and hold ON/OFF key and 4 key at the same time until the WEIGHT window   
      shows “SETUP” . Under this mode, you can set the RS232 baud rate, data format and communication format. 
2.    After entering into this mode, the weight window will show “Setup”, the UNIT PRICE window will show “232.oUt”   
      (RS232 output   
      content format) and the TOTAL PRICE window shows one of following content: 

2.1 HOST

HOST

HOST

HOST (US-PC-PH/PL-xxxx is connected with host device, e.g. a PC) 

2.2  P

PP

Prtd

rtd

rtd

rtd40

40

40

40 (US-PC-PH/PL-xxxx is connected with the OS-2130D, label dimension is 58mm × 40mm, date will be 

printed on label) 

2.3  P

PP

Prtd

rtd

rtd

rtd60

60

60

60 (US-PC-PH/PL-xxxx is connected with the OS-2130D, label dimension is 58mm × 60mm, date will be 

printed on label) 

2.4  P

PP

PrtNd

rtNd

rtNd

rtNd4 

4 (US-PC-PH/PL-xxxx is connected with OS-2130D, label dimension is 58mm × 40mm, no date will be 

printed on label) 

2.5  P

PP

Prt

rt

rt

rtNd6

Nd6

Nd6

Nd6 (US-PC-PH/PL-xxxx is connected with the 2130D, label dimension is 58mm × 60mm, no date will be 

printed on label)   

Use numerical keys 0

00

0,1,2,3,4

,1,2,3,4

,1,2,3,4

,1,2,3,4 to choose RS232 output content format (0-HOST, 1-    P

PP

Prtd

rtd

rtd

rtd40

40

40

40, 2-    P

PP

Prtd

rtd

rtd

rtd60

60

60

60, 3-    P

PP

PrtNd

rtNd

rtNd

rtNd4

44

4,                     

Summary of Contents for US-PC-PH-15

Page 1: ...US US US US P P P PC C C C PH PH PH PH US US US US P P P PC C C C PL PL PL PL User Technical Manual Contents subject to change without notice Version 1 0 01 2022...

Page 2: ...g 10 6 6 6 6 Auto Auto Auto Auto off time setting off time setting off time setting off time setting 11 7 7 7 7 Display A D inner code and working voltage Display A D inner code and working voltage Di...

Page 3: ...n storing the scale for extended periods the battery must be charged every 60 days to avoid premature performance degradation If the operating time is no longer acceptable even after recharging the ba...

Page 4: ...us use when backlight is on with 12 hour recharge time when the battery voltage is below 5 6v Lo bat is displayed and beep for 10 seconds and then auto off Platter size LxD 288x210 2 2 2 2 Unpacki Unp...

Page 5: ...d US PC PL Follow below procedure to install the tower display 1 Pass the socket on bottom of scale base through the pole bracket and plug it to the connector 2 Connect the column to the base and tigh...

Page 6: ...splay reading is net weight tare is not not not not 0 SAVE SAVE SAVE SAVE Unit price fixing indicator k k k kg g g g lb lb lb lb oz oz oz oz Weight unit indicator UNIT PRICE UNIT PRICE UNIT PRICE UNIT...

Page 7: ...Used to clear the recorded data ENT ENT ENT ENTER ER ER ER Used to confirm the operation or entered data SAVE SAVE SAVE SAVE Save the tare weight and unit price when input the unit price so that the...

Page 8: ...lay A D inner code or working voltage ON OFF ON OFF ON OFF ON OFF 4 4 4 4 Used to enter RS232 parameters setup mode ON OFF ON OFF ON OFF ON OFF 5 5 5 5 Used to enter the date and time setup mode ON OF...

Page 9: ...g to resolve 4 To change the weighing unit of measure press the Unit key to toggle between kg lb or oz 5 Set the tare weight if desired 6 Place objects on the scale platter and read the weight on the...

Page 10: ...press the RC PLU key Press the ON OFF key to return to weighing Note Note Note Note The previously stored tare weight can only be recalled with the RC PLU key when in tare setting mode c To clear the...

Page 11: ...it total value Note After unit price is entered if there is no operation in 3s the scale with automatically confirm the unit price and exit the mode If under non save mode the unit price will be clear...

Page 12: ...it tare the UNIT PRICE window displays the entered data 14 Use the numerical keys 0 9 CLEAR key to input the tare weight use ENTER key to store and confirm 15 The TOTAL PRICE window displays ItEm C se...

Page 13: ...ime till the UNIT PRICE window shows CodE 2 to enter this mode Now WEIGHT window will show UoL x x Voltage x x V this means the inner working voltage is x x V If the scale uses AC power adaptor the vo...

Page 14: ...r key to confirm the input and go to the next step or use ON OFF key to exit this mode 6 Then the UNIT PRICE window shows USb oUt USB output content format and the TOTAL PRICE window shows HOST the sc...

Page 15: ...igits P Total Price If the weight window display zero it will be unit price W Weight C Check sum for all characters Press ENTER key to confirm press ON OFF key to exit Note if the price weight or code...

Page 16: ...ing Date and time setting Date and time setting 1 Under the normal working mode press and hold 5 and ON OFF key for more than 3s to enter into this mode In this mode you can set the system date and ti...

Page 17: ...setting 1 Under the normal working mode press and hold 6 and ON OFF key for more than 3s to enter this mode In this mode you can set ID code Note the data will be lost after the scale reset 2 The wei...

Page 18: ...xls files The following is Example for US PC PH 1530 2 Software searches all serial ports on PC and tries to connect with the scale In the Status bar it will separately display present serial port bau...

Page 19: ...US PC PH US PC PL 17...

Page 20: ...the information of PLU1 250 Download successful will be displayed after downloading finished In downloading to use Serial Download Stop or F9 can stop down load PLU 6 Choose Upload in Serial menu the...

Page 21: ...alibration mode the WEIGHT window will display CAL ON which means the calibration switch is on The UNIT PRICE window displays Unit 0 or Unit 1 which means the chosen calibration weighing unit is kg Un...

Page 22: ...window and then please remove any weight on the scale 7 When the WEIGHT window displays unLoAd again the scale is ready to re confirm the zero point remove any weight on the scale after the scale is r...

Page 23: ...splay not go to 0 Something wrong with the keys or faulty PCB board or Load cell Check the key button Replace the PCB or load cell Missing segment or marks on LCD LCD connect pin broken Replace LCD Po...

Page 24: ...dust proof wash Clear the objects Replace the load cell Calibration can t be finished The inner code at zero point is too small or too big not enough with the full capacity inner code not stable ther...