background image

 

- 13 - 

Recommended cleaning methods;       

Table 2

 

Items 

Methods 

Times 

Body 

Wipe it with a soft cloth and mild detergent; 

daily 

Control panel 

Turn off valves when not in use; 

Wipe panel and control valve knob with mild 

detergent. 

daily 

Catch tray 

Pull out catch tray from front body until the 

equipment  cools  down.  Clean  grease  and 

other crumbs. Reinstall after cleaning. 

Warning: if the catch tray is permitted to fill 

too high, should be cleaned! 

Per use 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for USFG-24

Page 1: ...top Griddles Operating Instructions Before you begin please read these instructions carefully to use this product correctly to make the product perform ideally and to avoid hazards Models USFG 24 USFG...

Page 2: ...a safe place for convenient reference and operation This instruction manual is subject to change without further notice and the manufacturer reserves the right of final interpretation The appliance is...

Page 3: ...3 Brief Introduction 3 Manufacturer s Authority and Responsibility 3 Parameter Specifications 4 6 Transport and Storage 6 Installation and Debugging 6 8 Safety Notices and Precautions 9 Operating Inst...

Page 4: ...oilers in our company production Which is quality designed reasonably structured conveniently operated durable and easily maintained It s equipped with a high efficiency stainless steel tubular burner...

Page 5: ...4 Parameter Specifications Outline Dimensions in USFG 24 USFG 36...

Page 6: ...5 USFG 48...

Page 7: ...torage During transportation handle carefully and keep upright to prevent damage of the product packing Wrapped equipment should not be in open air for a long time and shall be placed in a well ventil...

Page 8: ...stallation position must be well ventilated in accordance with the local regulations The char broiler must be installed under the matched cooking fume exhauster according to the local regulations Impo...

Page 9: ...move top panel and needle type pressure joint screw arbor Fig 1 then slip rubber tube of pressure gauge over needle type pressure joint Start the equipment in accordance with the instructions measurin...

Page 10: ...ring operation do not directly touch burners and plates Turn off the equipment while cleaning servicing or adjusting any parts or attachments If the equipment has any problems of equipment damage gas...

Page 11: ...ain fire control valve knob anticlockwise after lighting the pilot light the main fire burner is lit by the pilot light The power of burner increases as revolving angle increases When knob reaches to...

Page 12: ...ge nozzle of another gas source then screw it Fig 5 Reinstall burner the pilot light head grill and control panel in proper place Caution Each main fire nozzle of the burner has been installed before...

Page 13: ...il on grill after cleaning Warning Before cleaning all control valves must be turned off Strictly follow the lighting instructions to use again after cleaning Warning Wait for the equipment to cool do...

Page 14: ...ntrol panel Turn off valves when not in use Wipe panel and control valve knob with mild detergent daily Catch tray Pull out catch tray from front body until the equipment cools down Clean grease and o...

Page 15: ...sound of fire 1 Insufficient gas pressure in pipe 1 Contact the local gas supply dept 2 Not match nozzle aperture with gas resources 2 Adjust nozzle diameter 3 Flow of connection pipe is not enough 3...

Page 16: ...ny has the right not to void warranty service Order replacement parts from authorized representatives and after sale service agency Provide the model number serial number and description when you orde...

Page 17: ...4 36 48 5 21202001002 bottom border package 1 610 670 257 USFG 24 21202002002 910 670 257 USFG 36 21202003002 1220 670 257 USFG 48 6 301080002 Galvanized flange face nut 4 M6 USFG 24 5 USFG 36 6 USFG...

Page 18: ...top 1 610 700 218 USFG 24 21202002001 910 700 218 USFG 36 21202003001 1220 700 218 USFG 48 17 301010007 U type burner 2 USFG 24 3 USFG 36 4 USFG 48 18 301030014 pressure maintaining valve 1 4 10 USFG...

Page 19: ...ng valve connects with air intake must be installed by authorized and licensed technicians to ensure interface tightness 2 Screw the hex nut Fig 9 before connect air intake ensure gas mark Fig 10 on t...

Page 20: ...nce charge But to update some components and necessary maintenance can prolong life length of the products Contact the dealer for assistance In order to avoid confusion please follow the format in fig...