11
1. Remove the tank from carton.
2. Verify the distributor tube is centered
in the bottom of the tank. A flashlight
may be necessary. There is a small
indentation in the bottom of the tank
that will allow the distributor tube to
drop in place. The top of the distribu-
tor tube will be flush with the top of the
tank when it is installed correctly.
Fusion Backwashing Filter Tank Preparation
WATER PRESSURE: A minimum of 30 pounds of water pressure is required for regeneration valve to
operate effectively.
ELECTRICAL FACILITIES: An uninterrupted alternating current (A/C) supply is required. Note: Other
voltages are available. Please make sure the voltage supply is compatible with the unit before instal-
lation.
EXISTING PLUMBING: Condition of existing plumbing should be free from lime and iron buildup. Pip-
ing that is built up heavily with lime and/or iron should be replaced.
LOCATION OF INFUSION TANK AND DRAIN: The Infusion tank should be located close to a drain to
prevent air breaks and back flow.
BY-PASS VALVES: Always provide for the installation of a by-pass valve if unit is not equipped with
one.
CAUTION: Water pressure is not to exceed 80 psi, water temperature is not to exceed 110°F (43°C),
and the unit cannot be subjected to freezing conditions.
Installation, Operation and Maintenance Manual
Models: 089-IF-150, 089-IF-250, 089-IF-400,
089-IF-500