US VACUUM RP50B-WS Installation And Operation Manual Download Page 3

SAFETY PRECAUTIONS 

CAUTION: When using PVC pipe or any static enhancing material for exhaust 

piping, make provisions to safeguard against arcing from static electricity. 

Arcing can ignite oil vapor that may be present. 

CAUTION: Do not operate the pump without the belt guard properly attached. 

Operating the pump without the belt guard secured in place exposes people in 

the vicinity of the pump to risk from rotating drive parts. 

CAUTION: Do not operate this pump in oxygen service. Oxygen service is  

defined as any application which has a process gas concentration that exceeds 

20%. Pumping oxygen enriched gases with mineral oil or other non-inert fluids 

can cause an explosion in the pump, resulting in damage or injury. 

CAUTION: Take precautions to avoid prolonged or excessive exposure to oil 

mist or process materials from the discharge of the pump. Do not discharge the 

pump into a closed room or a room without adequate ventilation. Always use a 

discharge oil mist eliminator unless the pump discharge is vented to the open 

air. Venting the outlet to open air is highly recommended 

CAUTION: Disconnect the pump from the electrical supply at the main  

disconnect before dismantling or servicing the pump. 

CAUTION: Lift only with the lifting eyebolts supplied with the pump. Do not lift 

equipment attached to the pump with the eyebolts supplied. 

CAUTION: Do not restrict the pump discharge line in any way, or place any 

valves in the discharge line. Excessive pressure build-up could cause damage 

or injury. 

CAUTION: Do not touch hot surfaces on the pump. In normal operation at  

low pressures surface temperatures will not normally exceed 160 Degree F.  

Prolonged operation at 200 torr may cause surface temperatures up to 200 

Degree F. 

Summary of Contents for RP50B-WS

Page 1: ...Rotary Vacuum Pump INSTALLATION OPERATION MANUAL US VACUUM PUMPS LLC P O BOX 909 CANTON TX USA 75103 TEL 888 416 7366 FX 877 416 7599 EMAIL USVACUUM EARTHLINK NET WWW USVACUUMPUMPS COM WARNING DO NOT...

Page 2: ...al systems including heavy Current Voltage installations Depending on the operating conditions particularly where dangerous conditions may be present improper handling could lead to severe personal in...

Page 3: ...or excessive exposure to oil mist or process materials from the discharge of the pump Do not discharge the pump into a closed room or a room without adequate ventilation Always use a discharge oil mi...

Page 4: ...TY PRECAUTIONS Page 2 INTRODUCTION Page 4 PERFORMANCE SPECIFICATIONS Page 6 DESCRIPTIONS Page 7 GENERAL INFORMATION Page 8 START UP Page 10 TROUBLESHOOTING Page 11 PARTS LIST EXPLODED VIEWS Page 15 WA...

Page 5: ..._____________________ Oil Type________________________________ Serial No ____________________________ Operating Vacuum________________________ Startup Date__________________________ Inlet Gas Composit...

Page 6: ...loading no pressure difference is required to operate this valve The outlet discharge valve is opened automatically by the compression of the air or gas in the pump against atmospheric pressure plus...

Page 7: ...densable vapors from the gas stream The RP 50B WS has been specifically designed to operate in these types of applications where water vapor contamination can cause reliability and longevity issues wi...

Page 8: ...cooler Control the water flow so the discharge temperature is between 95 110 deg F when incoming water is between 50 70 deg F Where the water is ex tremely cold control the flow so the pump runs just...

Page 9: ...clean vacuum installation C Standard threaded piping however is satisfactory and more readily installed The piping should be Carefully cleaned to remove any scales or chips Blow out any loose material...

Page 10: ...to the full load motor current listed on the nameplate Wire the solenoid valve to allow oil flow from the pump oil reservoir to the pump bearings internals AFTER ELECRICAL CONNECTIONS HAVE BEEN MADE...

Page 11: ...Generation On seal oil vacuum applications large amounts of water vapor is often distilled out of the seal oil from the degassifiaction tank with the water vapor entering the seal oil vacuum pump The...

Page 12: ...ospheric air into the pumping chamber to aid in removing condensable vapor contaminates from the vacuum pump oil Vapor contaminates in the pump oil can dramatically impair the pump performance by vapo...

Page 13: ...the oil and the gases being pumped White milky oil is an indication of water contamination use gas ballast to clear oil or change oil Water can also be removed by draining water from the pump oil drai...

Page 14: ...king Remedy Tighten if necessary Possible cause Exhaust valve not sealing Remedy Disassemble and clean if necessary Possible cause Threaded connections leaking Remedy Paint with vacuum sealant Possibl...

Page 15: ...exhaust side or expels oil droplets from the exhaust Possible cause No exhaust filter in place Remedy Install exhaust filter Possible cause The exhaust filter is not properly seated with the o ring in...

Page 16: ...16 RP 50B PUMP PARTS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22...

Page 17: ...PIN 5 ENDPLATE A 6 ENDPLATE B 7 SHAFT 8 SHAFT SEAL HOUSING 9 BUSHING 10 WOODRUFF KEY 11 SNAP RING 12 13 O RING 14 DISCHARGE VALVES 15 VALVE COVER 16 VALVE COVER GASKET 17 HOLD DOWN PLATE 18 GASKET HO...

Page 18: ...tems must be held for seller s inspection and returned to sellers Ex works point upon request THERE ARE NO WARRANTIES EXPRESSED IMPLIED OR STATUTORY WHICH EXTENDS BEYOND THE DESCRIPTION ON THE FACE HE...

Page 19: ...19 NOTES...

Reviews: