3.3.3 Channel

On this page, you can view all of the supported LoRa frequencies and setup the channel
frequency used for receiving and sending data.

Note

: Make sure the you have configured the corresponding channel on the gateway.

E.g. If you have configured a 923.2 MHz channel on UC11-T1, then you have to configure a 923.2
MHz channel on gateway as well.

Summary of Contents for UC11-T1

Page 1: ......

Page 2: ...way 15 4 3 Add Devices to Ursalink Cloud 17 4 4 Check the Data of UC11 T1 20 4 5 Configure UC11 T1 via Ursalink Cloud 20 4 5 1 Basic Settings 21 5 Configuration via TTN 23 5 1 Add a LoRaWAN Gateway to The Things Network 23 5 1 1 Register Your Gateway in The Things Network 23 5 1 2 Connect Ursalink gateway to The Things Network 24 5 2 Add UC11 T1 To The Things Network 26 5 2 1 Create an Application...

Page 3: ...sor can measure temperatures from 40 C to 70 C as well as air humidity from 0 to 100 The sensor is optimized for long battery life and excellent RF performance It is fully configurable over the air by the user for custom applications thresholds trigger events and reports This user guide is intended to provide detailed technical specifications and explanations to basic users as well as the technica...

Page 4: ...he Ursalink UC11 T1 Step 3 Run the Ursalink ToolBox Parameter Item Reference Scope Measuring Range Accuracy Temperature 0 3 C from 0 C to 70 C 0 6 C from 40 C to 0 C Humidity 3 RH from 10 to 90 5 RH below 10 and above 90 Frequency Band EU 433 CN 470 510 EU 863 870 US 902 928 AU 915 928 KR 920 923 Antenna Embedded Ceramic antenna Operating Temperature 40 C to 70 C 40 F to 158 F Relative Humidity 0 ...

Page 5: ...ial port parameters Serial Port Settings Item Description Default Serial Port Select the serial port for data transmission Null Login Password Enter the correct password to login 123456 Baud Rate Select from 9600 57600 115200 57600 Data Bit Select from 5 7 8 8 Parity Bit Select from Even Odd None None Stop Bit Select from 1 2 1 ...

Page 6: ...atus Click Status to see the basic status information of this device Status Item Description Local Time Show the time of the device Join Status Show if the device join the network successfully The Activate means the device has joined the network RSSI SNR Show the RSSI SNR of received packet ...

Page 7: ...dity value Battery Show the battery level Uplink Frame counter The number of data frames sends uplink from UC11 T1 to the network server Downlink Frame counter The number of data frames sends downlink from the network server to UC11 T1 3 3 LoRaWAN 3 3 1 Basic OTAA ...

Page 8: ...vated by personalization Activation by personalization directly ties an end device to a specific network by passing the join request join accept procedure OTAA Application Key Enter the application key Whenever an end device joins a network via over the air activation the application key is used to derive the Application Session key 5572404c6 96e6b4c6f 526132303 13823 Reporting Interval The UC11 T...

Page 9: ... device will send an alarm notification to Network Server if the temperature goes above below temperature thresholds Disabled greater than Enter the maximum temperature threshold Null less than Enter the minimum temperature threshold Null Note If you set a lockout time of 10s a continued time of 5s the alarm will be triggered as soon as the temperature goes above the maximum temperature threshold ...

Page 10: ...go through a new join procedure every time it has lost the session context information ABP Activation by Personalization Under certain circumstances end devices can be activated by personalization Activation by personalization directly ties an end device to a specific network by passing the join request join accept procedure OTAA Device Address Enter the device address The device address identifie...

Page 11: ... device will resend regular report confirmed packets 3 times at most Disabled Alarm Report Confirmed After sending the attribute package or alarm packet to the network server if the device does not receive ACK bit from the Network Server then the device will resend the packet Note If the device doesn t receive ACK for a long time the device will resend regular report confirmed packets 3 times at m...

Page 12: ...ncies and setup the channel frequency used for receiving and sending data Note Make sure the you have configured the corresponding channel on the gateway E g If you have configured a 923 2 MHz channel on UC11 T1 then you have to configure a 923 2 MHz channel on gateway as well ...

Page 13: ...ect the correct firmware file from the PC Step 5 Click Upgrade and the device will check if the firmware file is correct If it s correct the firmware will be imported to the device and the device will reboot after upgrading is completed Note Any operation on Ursalink ToolBox is not allowed during upgrading otherwise the upgrading will be interrupted or even the device will break down ...

Page 14: ...unt with Ursalink Cloud follow these steps 1 Go to https cloud ursalink com login html to register a Ursalink Cloud account 2 Log in to Ursalink Cloud after the email has been verified Note It is important that you have access to the verified email address before proceeding ...

Page 15: ...the Ursalink Cloud please follow these steps 1 On the main page click Gateway 2 On the gateway page click Add to add a gateway Enter the correct SN of the gateway and click Add You can find your gateway SN either on the label on the bottom of the device or on the web GUI ...

Page 16: ...16 Note Please make sure the working mode of gateway is Ursalink Cloud Once the device has been added successfully You will see the device in the list ...

Page 17: ...s to Ursalink Cloud To add a UC11 T1 to Ursalink Cloud please follow these steps 1 Click to go to the configuration page of this gateway 2 Click then click Associated Devices 3 Click Add to add a UC11 T1 to this gateway ...

Page 18: ...ick Add Sensor SN can be found on the bottom of the sensor 5 Once the device has been added successfully You will see the device in the list You can also add UC11 T1 directly to the main page please follow these steps 1 Click Add on the upper left corner ...

Page 19: ...19 2 Enter the correct SN of UC11 T1 and select the correct gateway Then click Add 3 Once the device has been added successfully You will see the device in the list ...

Page 20: ...ackets to view the data transmission You can see the basic status of the UC11 T1 on the Ursalink Cloud main page 4 5 Configure UC11 T1 via Ursalink Cloud Click to go to the configuration page of UC11 T1 You can edit the basic information of the device on this page ...

Page 21: ...r the custom name of this device LoRaWAN Temperatu re Humidity Sensor Application Key Enter the application key Whenever an end device joins a network via over the air activation the application key is used for derive the Application Session key 5572404c6 96e6b4c6f 526132303 13823 ...

Page 22: ...ill send an alert to Ursalink Cloud if the temperature goes above below temperature thresholds Disabled greater than Enter the maximum temperature threshold Null less than Enter the minimum temperature threshold Null Note If you set a lockout time of 10s a continued time of 5s the alarm will be triggered as soon as the temperature goes above the maximum temperature threshold or goes below the mini...

Page 23: ...eway to The Things Network 5 1 1 Register Your Gateway in The Things Network To register your gateway in the The Things Network please follow these steps 1 Click GATEWAYS on the console screen 2 Click register gateway 3 Enter the gateway information ...

Page 24: ...1 2 Connect Ursalink gateway to The Things Network To connect your gateway to TTN please follow these steps 1 Log in gateway web GUI 2 Click LoRaWAN Packet Forwarder General to configure the general setting ...

Page 25: ...25 3 Click Radios to configure the center frequency and channels ...

Page 26: ... All gateways connected to TTN servers forward all LoRaWAN data traffic to the TTN message router The TTN network server filters LoRa traffic by Application ID so that the data is routed to the correct user application and users are only able to access data from devices registered to their account To add an application follow these steps 1 Click APPLICATIONS located on the Console page 2 Click add...

Page 27: ...k Register Device under Devices in the application overview page 2 Enter the Device ID This ID must be unique on the user s account We recommend using the convention dev for device followed by the Sensor Dev EUI For instance if the device has a Dev EUI of 0025ca000000000f then the Device ID is dev 0025ca000000000f 3 Enter the Device EUI App EUI and App Key of UC11 T1 Note Please go to APPLICATION ...

Page 28: ...28 4 Click Register to complete registration 5 2 3 Configure UC11 T1 Connect T1 to PC and configure it via Toolbox ...

Page 29: ...29 5 3 Check Data Transmission on The Things Network 1 Click Gateways to check the Gateways status 2 Click Applications and select the Applications then go to Data you can find the data from UC11 T1 End ...

Reviews: