8
−−−−
sec.3e
2 VOICE - Technical Manual
PUSH BUTTON PANEL
PUSH BUTTON PANEL SINTHESI STEEL
VIDEO DOOR UNIT WITH 2 BUTTONS Ref.1083/63 (2 MODULES – 60 Hz)
PUSH BUTTON PANEL SINTHESI STEEL
OPERATION
CALLS
Up to 64 users max. can be called by pressing the respective buttons
of the push button panel associated to the camera.
After pressing the call button, the two following cases can occur:
The line is free: the door unit emits a con
fi
rmation tone and the
call is sent to the selected user.
The line is busy: the door unit emits an alert tone and the yellow
led on the front blinks (when the busy time is elapsed, the call
must be sent again).
If in the system there is a concierge switchboard in “Day”
mode, all the calls performed from the main call stations
are intercepted and managed by the switchboard.
PEDESTRIAN ELECTRIC LOCK MANAGEMENT
Door units are provided with two terminal pins for pedestrian electric
lock activation (SE-, SE+). The electric lock is activated in the following
cases:
Each time the entrance hall button is pressed (terminal pins PA,
CT).
After receiving a door lock release command from an apartment
station, according to the con
fi
guration of the dip-switch used to
con
fi
gure the operating mode “free” or “secret”.
When the call is sent to an apartment station which is provided
with “automatic door lock release” feature and this function is
active.
If electric locks to be activated need special timing, the rotary switch
“DOOR TIME” must be adjusted.
During electric lock activation, additional name holders, if
powered by door unit terminal pins ILL, switch off.
DRIVEWAY DOOR LOCK MANAGEMENT
Door units are provided with two terminal pins (SE2) connected to the
contacts of a normally open relay, that can be used to command a gate
opening control panel. The relay is activated for 1 sec. after receiving
a driveway door lock release command from an apartment station,
according to the con
fi
gured operation mode, “free” or “secret”, as for
the pedestrian electric lock.
This relay is NOT suitable to manage directly power loads,
but can only be used as command relay.
AUDIO ADJUSTMENT
Audio levels are trimmed in factory, so they don’t need to be changed
in most installations.
If it is necessary to change them, use a screwdriver on the suitable
adjusting points.
•
•
•
•
•
NAME HOLDERS LIGHTING
If the call station has more than 32 name holders, an additional
transformer must be used for button modules lighting. In this case,
the terminal pins “ILL” of the call station must not be connected to the
button modules.
The transformer Ref. 9000/230 can provide 11,2 W power, that is up
to 64 name holders max.
The number of name holders could be reduced according
to distance and section of the used cable.
PROGRAMMING DATA DELETING
To delete all the data programmed in the advanced con
fi
guration,
follow the instructions below:
Go to advanced con
fi
guration.
Keep any button pressed for 5 seconds at least. The door unit
emits a
fi
rst acoustic signal after 3 seconds and another one
longer after 2 seconds, to con
fi
rm the deleting.
•
•