37
EN
Antenna included
YES (coaxial cable not supplied)
LED Bulb
E14 24V 10W (included)
Power cable
≥
0.5
mm² x2
(not included)
Bulb connection
polarized at the electronic card connection.
power supply
24 V DC
Operating temperature
-20°C~+50°C
Dimensions
74 x 167 x 59 mm
Protection rating
IP54
Blinker
Detection Method
infrared beam
Sensing Range
20 m max
Input Voltage
AC/DC 12~24V
Response Time
< 100ms
Operation Indicator
RX : Red LED On (beam broken) / Off (beam aligned)
TX : Red LED On (power supply)
Dimensions
95 x 45 x 43 mm
Output Method
relay output
Protection rating
IP54
Photocells
Racks
Racks
12 x 34 cm
Material
nylon with steel insert
Length included
4 m (34 cm for each rack)
Channels
4
Frequency - Maximum transmitted power
433.92 MHz - <1mW
Power supply
1 CR2032 lithium battery (supplied)
Safety
rolling code technology
Free-field range
60 m
Remote control
F- MAINTENANCE
F- MAINTENANCE
Conduct the following operations at least every 6 months. If in high intensity of use, shorten the period in between.
Disconnect the power supply:
(1) Clean and lubricate the screws, the pins, and the hinge with grease.
(2) Check the fastening points are properly tightened.
(3) Make the wire connection are in good condition.
Connect the power supply:
(1) Check the power adjustments.
(2) Check the function of the manual release.
(3) Check the function of photocells or other safety device.