P16
DS1054-055A
Wiring via MTR2000ERP(X)
Wiring via MTR2000MRP(X)
230V ~
N L
C1 N
C2
BP
L
(*)
1
2
3
4
5
6
(*)
Pairing the wireless receiver to the thermostat
▶
On the THERMARP thermostat, open the thermostat configuration menu by holding the
button
pressed for 3 seconds until the
CLOCK
icon starts flashing.
▶
Use the arrows
and
to move through the various items of the configuration
menu until the RF WIRELESS
menu is displayed. Tap on the “Validate” icon
.
A
B
Always make sure that the MTR module is configured with the default values.
(*)
Warning!
Where it is necessary to guarantee galvanic insulation to the boiler, it is
essential to interpose the REL1C accessory (See diagram SD542-6054 in the product
data sheet of the MTR2000)
.