![urmet domus 2voice Sinthesi 1083/9 Manual Download Page 12](http://html1.mh-extra.com/html/urmet-domus/2voice-sinthesi-1083-9/2voice-sinthesi-1083-9_manual_1062542012.webp)
1
DS1083-034A
DESCRIPTION OF TERMINALS
]
LINE Bus line in
SE+ Positive for pedestrian crossing electric lock
SE-
Negative for pedestrian crossing electric lock
A
[
V3 Control camera signal
V5 Reference for control camera signal
B
[
V3 Control camera signal / video switch
V5 Reference for control camera signal / video switch
]
ILA
Output of device for deaf people
]
SE
Driveway electric lock activation
T+
Command for video switch
T-
Reference for video switch
CT
Reference for PA and SP
PA
Hall button
SP
Open door detector
]
ILL Power supply for name tags lighting
-
Local power supply negative
+
Local power supply positive
EXP
Connector for 16 users expansion modules
IC Connector for module with voice messages and led Ref. 1158/47
DOOR UNITS CONFIGURATION
=
=
ON
ON
AUX
ON
DIP
4
3
2
1
5
0
5
3
8
4
9 1
6
2
7
ON
DIP
4
3
2
1
5
0
5
3
8
4
9 1
6
2
7
DOOR
TIME
ID
CONV
TIME
Default settings
: default indoor station settings are:
PE type:
main
Secondary number:
0
Door opener:
free
Interruption:
Not assured
Guaranteed conversation time rotary:
30 s (pos 3)
Door lock release rotary:
1 s (pos 0)
Door unit number:
0
ID
:
door unit number
Set a number from 0 to 3 if the door unit is a main unit (v. AUX) or from 0 to 31 if the door unit is a secondary
unit as shown in the following figure.
There must not be two main stations with the same ID. Two secondary stations may coexist with the
same ID but with different address (v. AUX).
The ID of the secondary door unit must coincide with the column ID set in the column interface 1083/50,
if present.
•
•