19
DS1719-001A
BUTTON FUNCTION
FUNCTIONS
MTR2000ER
MTV500ER
MVR500ER
Function 1*
Power on / off
Change / off
Up / stop / down
Function 2
-
Memory on
Intermediate position
Function 3
On
On
Up / Stop
Function 4
Off
Off
Down / Stop
*
Default configuration
To changing the function of a button:
1 - Briefly press any button on the video door phone (Yokis Configuration Menu) 10 times. The video door
phone LED will blink rapidly.
2 - While the LED is blinking, press the chosen button from
1 to 4
and select the desired function: from
1
to 4
, see above.
3 - The LED will blink from
1
(or
4
) times to confirm calibration.
Restoring a video door phone Yokis Button to default settings
Default setting = delete button connections, return to function 1 (bistable), return to direct mode.
1 - Briefly press either Yokis button (Yokis Configuration Menu)
10
times. The video door phone LED will
blink rapidly.
2 - While the LED is blinking, rapidly press the button that you want to return to default setting
15
times.
3 - After pressing
15
times, the LED will blink 5 times to confirm.
Complete restore of the two video door phone Yokis buttons to default settings
1 - Briefly press either Yokis button (Yokis Configuration Menu)
10
times. The video door phone LED will
blink rapidly.
2 - While the LED is flashing, press either of the two Yokis buttons
25
times.
3 - After pressing
25
times, the LED will flash to confirm that default settings have been restored.
For more information and detailed configurations, consult the documentation on the two-button remote
controls on the www.yokis.com website.
TECHNICAL SPECIFICATIONS
Power voltage: ...............................................................................................................................
36 ÷ 48 V
Consumption: ....................................................................................................................................
@ 48 Vcc
Standby: ....................................................................................................................................
< 3,5 mAcc
Full rate: ...................................................................................................................................
< 245 mAcc
Dimensions (WxHxD) .....................................................................................................
202 x 142 x 23,5 mm
Wires with cross-section area of 0.5 mm
2
or larger must comply with IEC 60332-1-2; wires with
crosssection area smaller than 0.5 mm
2
must comply with IEC 60332-2-2.
KEY TO SYMBOLS
Symbol
Description
Direct input voltage
See the installation manual of the device
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, URMET S.p.A. declares that the radio equipment type:
2 VOICE VIDEO 7” SOFT TOUCH
Ref.
1719/1
is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address:
www.urmet.com