3.5 PROGRAMMING PROCEDURE OF ATT2 RELAY ACTIVATION TIME
It is possible to program activation times of the ATT2 actuator relay. After entering in the programming
procedure following the previously described steps, enter the number of parameter 04 and the desired
value, according to the table below. By default, is set the value 1, i.e. 1 second.
Parameter
04
Value
1
2
3
4
Activation type
1 s
2 s
4 s
10 s
3.6 FLASH TIME (R) PROGRAMMING PROCEDURE
It is possible to program the FLASH identi
fi
cation time (button R). This time depends on the telephone type
used in the system; for Italy is usually 100 milliseconds, but for other countries and telephones it could be
necessary to change it. After entering in the programming procedure following the previously described
steps, enter the number of parameter 05 and the desired value, according to the table below. By default, is
set the value 1, i.e. 100 ms.
Parameter
05
Value
1
2
3
4
5
Activation type
100 ms
270 ms
400 ms
600 ms
900 ms
The FLASH button is the same as R button.
3.7 PROGRAMMING PROCEDURE FOR THE DURATION OF THE DOOR PHONE
CALL
It is possible to program the door phone call duration time.
After entering in the programming procedure following the previously described steps, enter the number
of parameter 07 and the desired value, according to the table below. By default, is set the value 2, i.e. 10
seconds.
Parameter
07
Value
1
2
3
4
Activation type
5 s
10 s
20 s
30 s
3.8 COUNTRY SELECTION
It is possible to select the country where the interface will be used. According to the country selection,
country speci
fi
c parameters will automatically change, as per the table below.
After entering in the programming procedure following the previously described steps, enter the number of
parameter 08 and the desired value, according to the table below. By default, is set the value 1, i.e. Italy.
Parameter
08
Value
1
2
3
4
5
6
7
8
9
Activation time
Italy
France Belgium
Israel
Holland Ireland
Czech
Rep.
Hungary
England
§
Factory values
table. At the power-up, are loaded the following parameters used for Italy, if they have not
been changed.
In case of a different country, identify the most similar characteristics among the desired ones.
Line
engagement
Combiphone
BCA
ATT1
relay
ATT2
relay
FLASH
Door
phone
call
Country Mode
A/B
TONE
Parameter
01
02
03
04
05
07
08
09
10
Italy
(default)
1
1
1
1
1
2
1
1
1
France
1
1
4
4
3
2
2
1
1
Belgium
1
1
1
1
1
2
3
1
1
Israel
2
2
3
3
4
3
4
1
1
Holland
1
1
1
1
1
2
5
1
1
Ireland
1
1
1
1
1
2
6
1
1
Czech
Republic
1
1
1
1
1
2
7
1
1
Hungary
1
1
1
1
1
2
8
1
1
England
1
1
1
1
1
2
9
1
1
3.9 A OR B MODE PROGRAMMING PROCEDURE
It is possible to program the interface mode in mode A or mode B.
After entering in the programming procedure following the previously described steps, enter the number of
parameter 09 and the desired value, according to the table below. By default, is set the value 1, i.e. mode
A.
Parameter
09
Value
1
2
Operating mode
A
B
In mode
A
, the trunk line is directly connected to the telephone as soon as the handset is picked up.
In mode
B
, the trunk line is not directly connected to the telephone and it is necessary to enter a code,
in order to seize it.
3.10 PROGRAMMING PROCEDURE FOR CONFIRMATION TONE OF A DOOR
UNIT
CALL
It is possible to enable a con
fi
rmation tone for a call coming from the door unit, i.e. after pressing the call
button, the external user will heard a tone that signals the call forwarding to the apartment.
After entering in the programming procedure following the previously described steps, enter the number
of parameter 10 and the desired value, according to the table below. By default, is set the value 1, i.e. the
con
fi
rmation tone is enabled.
Parameter
10
Value
1
2
Call tone on door unit
ON
OFF
§