DS1092-041C
47
DOME SETTINGS
The external dome and the internal dome must be removed in the following manner to set the address, the
baud rate and the communication protocol:
7.
Turn the external dome anticlockwise by approximately ¼ a turn to release it from its seat.
8.
Turn the internal dome anticlockwise by approximately ¼ a turn to release it from its seat.
9.
After removing the two parts, access the dip switches inside the dome.
10. Use the small screwdriver (included) for making the necessary settings.
11. Position the internal dome on the support making the holding tabs of the dome itself with the holes on
the support and turn it clockwise until it locks.
12. Position the external dome on the support and turn it clockwise until it is blocked.
SETTING THE ADDRESS
The default address of the THERA 4 dome is 1.
To change the address according to the connected devices, use the dip switches on the PCD of the dome
as shown in the figure.
DEFAULT SETTINGS
DOME ADDRESS CALCULATION EXAMPLE
(2+4+16=22) The address is 22
1 2
ON
3
4
5
6 7 8
ON
1
2
3
4
5
6 7 8
1
2
8
128
64
16
4
32
1 2
ON
3
4
5
6
7
8
DIP SWITCH
Summary of Contents for 1092/601 THERA 4 MINIDOME P/T/Z
Page 135: ...DS1092 041C 135 ...