42
DS1092-041C
EXPOSURE
This function is used to adjust the dome lens functions.
Select this menu item and press OPEN to access the following submenu:
EXPOSURE SETUP
BRIGHTNESS
41
■■■■■■■█■■■
IRIS
MANUAL
SHUTTER MANUAL
AGC
NORMAL
SSNR
HIGH
SENS-UP OFF
END
Option
Value
Explanation
BRIGHTNESS
0 - 100
This setting is used to adjust the brightness of the
image.
IRIS
AUTO - MANUAL
This is used to select the required adjustment type
of opening and closing the camera iris.
SHUTTER
MANUAL - A.FLK -
---
This is used to determine the CCD exposure time
for adjusting the camera shutter opening.
AGC
NORMAL - HIGH -
OFF
This is used to select or deactivate an AGC value.
SSNR
LOW - MIDDLE -
HIGH - OFF
This is used to select or deactivate a noise
reduction value.
SENS-UP (DSS)
AUTO - OFF
This is used to activate/deactivate the sensitivity
function (DSS) of the camera according to light
variations.
END
/
This is used to quit the submenu.
BRIGHTNESS
Select BRIGHTNESS and press the arrow buttons to vary the light percentage.
IRIS
Select IRIS and select the options: MANUAL and AUTO.
Select MANUAL and press OPEN to access the following submenu:
IRIS MANUAL SETUP
IRIS
VAL
85
■■■■■■■█■■■
END
Summary of Contents for 1092/601 THERA 4 MINIDOME P/T/Z