26
DS1092-525
ALARM - ALARM MOTION MANAGEMENT
ALARM
VIEW TYPE
ALL
OSD VIEW
ON
ALARM OUT
ON
TIME
■■█■■■■■■
3
RETURN
RET
In the ALARM submenu you can configure the alarm specification the operator can display if a movement
happens in the previously sensitised area(s). Available options if enabling the VIEW TYPE function: ALL
(displays the box and the frame), OUTLINE (displays the frame only), BLOCK (displays the box only). The
OSD VIEW option displays an alarm message too. The ALARM OUT, ALARM SIG. and TIME options are
not enabled in this camera.
PRIVACY – MASKING ONE OR MORE ZONES OF THE SCENE
The PRIVACY function allows to define up to 4 privacy zones that mask specific areas. A privacy zone is
displayed on the monitor as a rectangle, with perimeter, dimensions, colour and transparence level
previously set by the user.
REMARKS ON PRIVACY ZONE
•
It is suggested to use privacy zones lightly bigger than areas to be masked.
•
Privacy zones can only be rectangular.
Select this option to activate (ON) the privacy zones and access the following submenu.
PRIVACY
SELECT
AREA1
DISPLAY
COLOR
COLOR
WHITE
TRANS.
1.00
DEFAULT
RETURN
RET
Option
Value
Description
SELECT
AREA1 ÷ AREA4
This option allows to select one or more of the 4 available
privacy areas. It is possible to define the number of areas
to be displayed on the screen and the size of each single
area. (see below).
DISPLAY
COLOR ÷ INV ÷
MOSAIC ÷ OFF
This option allows to define dimension and position on the
screen of the selected area and type of mask: full color,
negative image or mosaic.
COLOR
CYAN ÷ USER ÷
WHITE ÷ BLACK ÷
RED ÷ BLUE ÷
YELLOW ÷ GREEN
It allows to select one of the available colors to fill the
previously selected area.
TRANS.
0.25 ÷ 1.00
It allows to set the transparency level.
DEFAULT
/
It allows to restore the default settings.