background image

1083/12 - 1083/15 - 1083/16

Configuration guide

System Type D

Summary of Contents for 1083/12

Page 1: ...1083 12 1083 15 1083 16 Configuration guide System Type D...

Page 2: ...ion How to use this Configuration Guide Menu structure Configuration procedure Programming proximity access keys Programming door open codes Appendix How to use this Configuration Guide Configuration...

Page 3: ...pe D One or up to a maximum of four Primary entry panels i e panels which call all apartments in the system One or more blocks maximum of 32 each with one or two Secondary panels which only call apart...

Page 4: ...the diagram on Page 1 to determine whether the panel you are configuring is Primary or Secondary It is not important whether Primary or Secondary entry panels are programmed first in fact a system can...

Page 5: ...E CODE TYPE BUSY TIME STOPABLE DOOR LOCK 1 RELEASE TIME DOOR LOCK 1 DOOR LOCK 2 RELEASE TIME DOOR LOCK 2 PASSWORD LCD BACKLIGHT BUTTON SOUND MULTITOUCH CALL WELCOME MESSAGE TIME ZONE DATE AND TIME DAY...

Page 6: ...d the screen is as follows On the entry panel keypad press 99999 and you will see this screen Enter 1000 the default password then press Use the and buttons to select LINGUA and press Use the and butt...

Page 7: ...You see this screen Press the button to select CONFIGURATION then press Use the or buttons to select YES and press CONFIGURATION LANGUAGE Page 5...

Page 8: ...entry Press and then enter the last block number 3 In this example Press In a system with only one primary entry panel the ID is always 0 In this case just press In a system with two three or four Pr...

Page 9: ...83 50 Riser Distributor to which the secondary panel is connected For example if the secondary entry panel being programmed is connected to a 1083 50 with the address then the RISE NUMBER is 2 5 4 1 3...

Page 10: ...nd also the solid state lock release output SE SE time For example for a time of 10 seconds press 1 0 Choosing FREE means that the door can be opened by the monitor or handset at any time without the...

Page 11: ...led Choosing SECRET means that the monitor or handset must be called before it can open the gate Use the or buttons to make a selection then press For an explanation of the three different lock output...

Page 12: ...ou wish to use this feature enter the apartment address then press Otherwise just press Page 7 Page 10 A WELCOME MESSAGE can be entered This is the message which visitors will see when they approach t...

Page 13: ...t OFF and press To use the POSTMAN function choose ON then press To modify the TIME ZONE select YES then press Choose EUROPE as the CONTINENT and press Choose BRITAIN UK for the COUNTRY and press Modi...

Page 14: ...TO time Enter the TO time and press Repeat for the remaining days The POSTMAN ICON which appears on the display can be T or P Use the or buttons to select T or P then press The VOCAL SYNTHESIS entry p...

Page 15: ...HBOARD Otherwise select OFF and press Page 13 The basic entry panel configuration is now complete The next step is to configure the block information is necessary to configure all blocks in the system...

Page 16: ...akes when finished Page 14 buttons to select buttons to select Enter a name for the first block maximum 12 characters is the block wh with address 00 See the site specific connection diagram for detai...

Page 17: ...ess Block A Apartment numbers 1 50 Block B Apartment numbers 51 100 Block C Apartment numbers 101 150 Block D Apartment numbers 151 200 1083 50 1083 20 1083 50 1083 20 1083 20 1083 20 1083 50 1083 20...

Page 18: ...m the entry panel the monitor with binary address 1 will ring Block A Apartment numbers 1 50 7 8 3 2 4 3 2 5 3 6 6 1 5 5 1 6 3 ON 7 7 8 1 8 2 4 4 6 ON 4 2 ON 8 5 7 ON 1 53 51 52 54 Monitor handset DIP...

Page 19: ...m the entry panel the monitor with binary address 1 will ring Block C Apartment numbers 101 150 7 8 3 2 4 3 2 5 3 6 6 1 5 5 1 6 3 ON 7 7 8 1 8 2 4 4 6 ON 4 2 ON 8 5 7 ON 1 153 151 152 154 Monitor hand...

Page 20: ...ntry panel it is necessary Page 18 nd 15 for the other blocks in the first Primary entry panel When all blocks have been configured in the first primary entry panel repeatedly press In a system with m...

Page 21: ...block name Use to correct mistakes Press Press Use the Use the Enter a name for the block Use the keypad characters to enter the block name Use to correct mistakes Press or or Enter a name for the bl...

Page 22: ...w programm Page 20 Page 14 OFFSET number if necessary explanation of OFFSET The entry panel is now programm Page 20 Page 14 number if necessary The entry panel is now programm number if necessary The...

Page 23: ...fault password then press Use the and buttons to select KEYS and press LANGUAGE KEYS Use the and buttons to select NEW and press Now hold a key to the entry panel reader You hear a beep and briefly se...

Page 24: ...er 1000 the default password then press Use the and buttons to select DOOR OPENER and press LANGUAGE DOOR OPENER Use the and buttons to select NEW and press Enter the code and press Note The code must...

Page 25: ...ELEASE TIME C NO NC Voltage free relay contact used to control fail safe releases or maglocks Can also be used to trigger automatic gates and doors Rated at 30V AC DC 3 5A The output is triggered by p...

Page 26: ...Notes Page 24...

Page 27: ...URMET COMMUNICATION AND SECURITY UK LTD Urban Hive Skyline 120 Avenue West Great Notley Essex CM77 7AA Tel 01376 556010 Fax 01376 567874 www urmet co uk sales urmet co uk...

Reviews: