1. Connect the mains power supply cables to the 2 terminals of the control panel power supply.
2.
Only for 1067/052A and 1067/092
: To connect the earth of the equipment, crimp the Faston terminal (
A
) (provided
with the system) onto the earth cable that will be inserted into one of the Faston terminals on the wall of the box (
C
)
and connect the small earth cable to the cover Faston (
B
).
3. Secure the wires by fastening them in anchoring point (
F
) with the strip provided.
IMPORTANT!
After having connected the wires, remember to insert the plastic protection on the terminals.
Figure 55 - Diagram of the connections to the mains power supply
IMPORTANT!
The system must be powered by the mains only when all the devices are installed correctly,
making it possible to proceed with their acquisition. For security purposes, close even the control panel casing
before powering it up.
5.12.2
Connecting the data Bus
Connect the terminals
+,
+D
,
D
and
─
the cable to the 4 wires of the bus; this will enable the communications among the
control panel, readers, keypads, any expansions present. The data bust requires no terminal resistors.
The cable shieldings can be connected together in the control panel at the negative pole (
─
) of the power supply.
Figure 56 - Connections via bus
demonstrates how to connect the various devices to each other via the bus line.
Figure 56 - Connections via bus
B
C
F
1067/024 - 1067/032A control panel
(
F
) Point where power cables are fastened with the band
1067/052A control panel
– 1067/092
(
F
) Point where power cables are fastened with the band
F
A
1067/024 -1067/032A - 1067/052A - 1067/092
SWITCH
THERMO-
MAGNETIC/
DIFFERENTIAL
MAINS
POWER
SUPPLY
SWITCH
DIFFERENTIAL
USERS