urmet domus 1033/470 Installation And User Manual Download Page 7

12

DS1033-124

13

DS1033-124

It is possible to check the current con

fi

 guration of a parameter, or if a value is correct, for example the 

stored telephone number, by digiting the respective parameter followed by the button 

 instead of button 

. This check function is not available for access password (parameter 660).

Warning

: if the telephone number associated to the call diversion function is the only programmed number, 

i.e. all the other telephone numbers are empty, in case of an alarm it will be called also if the call diversion 

function is disabled.

The SMS message text is preset by default and can not te customized by the user. It is only possible to 

enable or disable the SMS message sending.

2.2.2 VOICE MESSAGES RECORDING

Alarm messages are composed by two parts: the basic message, the same for all the alarm messages, and 

the event message, associated to the input that detected an alarm condition. 

The basic message may last up to 15 seconds and must contain information as place and address where 

the alarm occurred. For example, a proper basic message might be: “Paolo Verdi’s apartment, via Roma 

15 Milano”. 

Every event message may last up to 5 seconds and should indicate the kind of the generated alarm, for 

example “Intrusion alarm”, “Boiler block”, “Flooded premises”, etc. It is suggested to avoid generic voice 

message, for example “Alarm input 2”. 

For messages recording is used the same telephone as for the programming procedure.

To stop recording before the available time is elapsed, press button 

.

Parameter Description

Allowed values

Factory 

value

Voice messages

400

Basic message

15 s

no

401

Input 1 event message

5 s

402

Input 2 event message

5 s

403

Input 3 event message

5 s

404

Input 4 event message

5 s

Message recording

To record a message, follow the instructions below:

User action 

Dialer answer

Enter the parameter associated to the 

message to be recorded, followed by 

button 

.

Start message recording after the acoustic signal

After the beep, start recording the 

message

When the available time is elapsed, the message is played. 

Recorded message...

Message playback

To listen again a recorded message, follow the instructions below:

User action 

Dialer answer

Enter the parameter associated to the 

message to be listened again, followed 
by button 

The recorded message is played, followed by beep-beep. 

If no message has been recorded, the dialer emits beep-

beep.

Message deleting

To delete a message, follow the instructions below:

User action 

Dialer answer

Enter the parameter associated to the 

message to be deleted, followed by the 

button 

.

Start message recording after the acoustic signal

Press again the button 

.

Recorded message

2.3 ADVANCED PROGRAMMING

The advanced programming concerns the con

fi

  guration of all the other dialer parameters. These con

fi

 gurations 

are strictly related to the system structure, to its wiring, to telephone networks characteristics and to desired 

functions, so it is not suggested the 

fi

 nal user access to the advanced programming procedure. Only the 

installer should perform this programming procedure.

2.3.1 INPUTS AND OUTPUT

The following table shows the different parameters used to con

fi

 gure inputs and output, allowed values and 

factory values.

Parameter Description

Allowed values

Factory 

value

Alarm inputs programming

201

Con

fi

 guration of alarm input 1

0 = N.C. alarm input

1 = N.O. alarm input

2 = not used input (no alarms are 

generated, even if the input is 

connected)

0

202

Con

fi

 guration of alarm input 2

203

Con

fi

 guration of alarm input 3

204

Con

fi

 guration of alarm input 4

Output programming procedure

301

Output enabling for telephone connection 

failure signalling (failure on PSTN line or 

GSM 

fi

 eld loss)

0 = signalling disabled

1 = signalling enabled: in case of 

failure, the output relay is activated

0

After entering the value, press the button 

 to con

fi

 rm.

It is possible to check the current con

fi

 guration of a parameter, or if a value is correct, by digiting the 

respective parameter followed by the button 

 instead of button 

.

Warning

: if the output is con

fi

 gured as Failure, the output remote activations are automatically disabled 

with DTMF commands.

2.3.2 TELEPHONE PARAMETERS

It is possible to con

fi

 gure the following functions related to telephone calls:

Dial tone check

: if enabled, the dialer checks the dial tone after seizing the line. If the dial tone is detected, 

the device starts dialling the number, otherwise (no dial tone), the front LED starts blinking red. 

Warning

if the dialer is not directly connected to the telephone line (PABX) this function must be disabled!

Answer check

: if enabled, the telephone dialer, after calling the number, checks the presence of the 

ring back tone (the called telephone is ringing) and wait until it is ended before playing the alarm voice 

message. If the signal continues for more than 45 seconds, the dialer hangs up. If the answer check is 

not enabled, or if no ring back tone is detected, the alarm voice message is played 3 seconds after the 

telephone number has been dialled.

Rings for incoming call

: it enables or disables the answer to incoming calls. The value 0 disables the 

answer, the other values (1, 3, 5, 7) indicate the number of rings after which the telephone dialer answers 

the incoming call.

Summary of Contents for 1033/470

Page 1: ...DS 1033 124 LBT 8355 Mod 1033 TELEPHONE DIALER Ref 1033 470 Ref 1033 471 Ref 1033 472...

Page 2: ...4 user defined recordable alarm messages 4 telephone numbers associated to every input 12Vdc 10 15Vdc nominal power voltage Programmable number of call cycles 1 5 Programmable call delay GSM field tes...

Page 3: ...elephone numbers associated to the alarmed input The message text is Urmet Security System Alarm on input X where X may be 1 2 3 or 4 and indicates the input in alarm state The other programmed voice...

Page 4: ...pause one of the available commands is entered 1 2 3 4 or 9 the alarm call cycle is stopped see paragraph Alarm calls cycle interruption and the selected remote device is activated the dialer sends t...

Page 5: ...ming procedure 301 Outputenablingfortelephoneconnection failure signalling failure on PSTN line or GSM field loss 0 signalling disabled 1 signalling enabled in case of failure the output relay is acti...

Page 6: ...S messages sending 0 SMS messages enabled 1 SMS messages disabled 1 Various programming procedures 630 Follow me function 0 function disabled 1 function enabled 0 660 Password configuration for access...

Page 7: ...associated to the message to be deleted followed by the button Start message recording after the acoustic signal Press again the button Recorded message 2 3 ADVANCED PROGRAMMING Theadvancedprogramming...

Page 8: ...entering the value press button to confirm It is possible to check the parameter current configuration or if a value is correct by entering the respective parameter followed by button instead of butt...

Page 9: ...irreversible and all configurations are deleted telephone numbers voice messages etc After a reset a new programming procedure is needed 3 MAINTENACE 3 1 CLEANING To clean the telephone dialer use a d...

Page 10: ...it along its guides 3 Put the SIM in the holder taking care contacts are visible and put again the holder in its housing when sliding the holder SIM contacts must face the GSM module WARNING correct o...

Page 11: ...of an alarm For the connection of the microphone used for environmental listening Ref 1061 003 use a twisted pair The line must not be longer than 100m in connection polarity must be respected The tam...

Page 12: ...5mm2 section cable Max distance from inputs activation contacts IN1 IN2 IN3 IN4 to the PSTN GSM dialer 150m with 0 5mm2 section cable Max distance from PSTN GSM dialer output relay to KLIMAT ZOOM chro...

Page 13: ...ef 39 011 24 00 000 RIC AUT Fax 39 011 24 00 300 323 Area tecnica servizio clienti 39 011 23 39 810 Fabbricato da Urmet Electronics Limited un azienda del gruppo Urmet Made in PRC Manufactured by Urme...

Reviews: