3.   Put again the support on the back lid, by blocking it with the latches.

WALL MOUNTING

For dialer support wall mounting, follow the instructions below:

1.   Place the support and mark the hole points for the two slots. 

2.   Drill the wall and insert screw anchors.

3.   Fix the support with the screws to the anchors. Slots allow to compensate hole misalignments, in order 

to 

fi

 x the dialer in perfect horizontal position.

4.2 CONNECTIONS

Inputs are always referred to GND. With a NC input, the alarm is generated when the input is opened; with 

a NO input, when the input is closed.

Warning: the dialer identi

fi

 es the alarm kind, according to the input in alarm state; if it is necessary to 

differentiate speci

fi

 c alarms, for example an intrusion alarm and a gas leak alarm, different signalling must 

be associated to different dialer inputs. 

To connect the dialer to the PSTN line, use a twisted pair; no polarity must be respected.

Warning: the telephone dialer must be the 

fi

 rst device connected to the incoming PSTN line, in order to seize 

the line 

fi

 rst in case of an alarm.

For the connection of the microphone used for environmental listening (Ref. 1061/003), use a twisted pair. 

The line must not be longer than 100m; in connection polarity must be respected.

The tamper line must be connected only if an alarm control panel is available.

LINE

PSTN incoming line

PHONE

PSTN outgoing line

+MIC

Environmental listening microphone input (positive pole)

-MIC

Environmental listening microphone input (negative pole)

IN1

Alarm line input 1

IN2

Alarm line input 2

IN3

Alarm line input 3

IN4

Alarm line input 4

C

Relay output – normally closed contact

NC

Relay output – common contact

NO

Relay output – normali open contact

+V

12Vdc power supply (positive)

GND

12Vdc power supply (negative)

SABI

Tamper line (input)

SABO

Tamper line (output)

4.3 GSM ANTENNA

In some cases the GSM 

fi

 eld can be too weak for the provided GSM antenna (1033/471 and 1033/472 

models), for example because the carrier GSM station is too far or the dialer position is not right, but it is 

not possible to change it. 

In these cases, replace the antenna with a model provided with extension cable (see Urmet catalogue).

4.4 CLOSING

Close the dialer with the front lid, by 

fi

 xing it with the screw and put on the central plate again.

When putting the lid, take care the tamper is closed correctly.

Summary of Contents for 1033/470

Page 1: ...DS 1033 124 LBT 8355 Mod 1033 TELEPHONE DIALER Ref 1033 470 Ref 1033 471 Ref 1033 472...

Page 2: ...4 user defined recordable alarm messages 4 telephone numbers associated to every input 12Vdc 10 15Vdc nominal power voltage Programmable number of call cycles 1 5 Programmable call delay GSM field tes...

Page 3: ...elephone numbers associated to the alarmed input The message text is Urmet Security System Alarm on input X where X may be 1 2 3 or 4 and indicates the input in alarm state The other programmed voice...

Page 4: ...pause one of the available commands is entered 1 2 3 4 or 9 the alarm call cycle is stopped see paragraph Alarm calls cycle interruption and the selected remote device is activated the dialer sends t...

Page 5: ...ming procedure 301 Outputenablingfortelephoneconnection failure signalling failure on PSTN line or GSM field loss 0 signalling disabled 1 signalling enabled in case of failure the output relay is acti...

Page 6: ...S messages sending 0 SMS messages enabled 1 SMS messages disabled 1 Various programming procedures 630 Follow me function 0 function disabled 1 function enabled 0 660 Password configuration for access...

Page 7: ...associated to the message to be deleted followed by the button Start message recording after the acoustic signal Press again the button Recorded message 2 3 ADVANCED PROGRAMMING Theadvancedprogramming...

Page 8: ...entering the value press button to confirm It is possible to check the parameter current configuration or if a value is correct by entering the respective parameter followed by button instead of butt...

Page 9: ...irreversible and all configurations are deleted telephone numbers voice messages etc After a reset a new programming procedure is needed 3 MAINTENACE 3 1 CLEANING To clean the telephone dialer use a d...

Page 10: ...it along its guides 3 Put the SIM in the holder taking care contacts are visible and put again the holder in its housing when sliding the holder SIM contacts must face the GSM module WARNING correct o...

Page 11: ...of an alarm For the connection of the microphone used for environmental listening Ref 1061 003 use a twisted pair The line must not be longer than 100m in connection polarity must be respected The tam...

Page 12: ...5mm2 section cable Max distance from inputs activation contacts IN1 IN2 IN3 IN4 to the PSTN GSM dialer 150m with 0 5mm2 section cable Max distance from PSTN GSM dialer output relay to KLIMAT ZOOM chro...

Page 13: ...ef 39 011 24 00 000 RIC AUT Fax 39 011 24 00 300 323 Area tecnica servizio clienti 39 011 23 39 810 Fabbricato da Urmet Electronics Limited un azienda del gruppo Urmet Made in PRC Manufactured by Urme...

Reviews: