urmet domus 1033/351 Installation Booklet Download Page 6

DS1033-100C 

6. 

Fix the plastic base to the door or window using at least 2 self-tapping screws >3,5 mm and verify the 
base forms a solid block with the surface to be protected. 

7. 

Put back the printed circuit board on the base and fix it. 

8. 

Connect the device to the alarm control panel and close the lid. 

 

WIRINGS 

Screw terminal strip description: 

+12V:

 

 

Positive supply 

0V:

 

 

Negative supply 

ALARM:

   

Normally closed alarm line wirings 

TAMPER:

 

Tamper wirings line 

LATCH: 

Positive supply related alarm memory input terminal (do not connect directly to Urmet 
control panel). 

 

 
 

CONFIGURATION 

 

 

At first power up of the sensor the green LED blinks for approximately 10 seconds and during this time the 
self-calibrating phase is performed (Jumper Range select 

– on). 

To  set  sensitivity,  turn  VR1  trimmer  in  anticlockwise  direction  and  hit  the  middle  of  the  surface  to  be 
protected. If the led lights up red or orange, remove selection jumper and select the low sensitivity range 
(low).  Increase  progressively  the  sensitivity  by  turning  VR1  in  clockwise  direction.  After  each  setting  hit 
again the middle of the area and check the led colour. The red led indicates the right sensitivity. If the led 
turns green, the sensitivity is too low and must be increased. If the led turns orange, the sensitivity is too 
high and must be reduced. 

Hole for routing cables 

Summary of Contents for 1033/351

Page 1: ...DS1033 100C LBT7994 SENSORE SISMICO A MICROPROCESSORE SHOCK SENSOR WITH MICROPROCESSOR Sch Ref 1033 351 LIBRETTO INSTALLAZIONE INSTALLATION BOOKLET Mod 1033 ...

Page 2: ...arantire la migliore rilevazione ed immunità a falsi allarmi Le principali caratteristiche del dispositivo sono le seguenti Ottima sensibilità Zona di rilevazione regolabile Doppio livello di sensibilità Immunità a falsi allarmi Impostazione led 3 colori programmabile Indicazione di colpo molto forte Indicazione di rumori di disturbo Relè ottico a bassa rumorosità Elettronica SMT Non necessita di ...

Page 3: ...H morsetto di ingresso per memoria allarme riferito a positivo Non utilizzabile direttamente con centrali Urmet CONFIGURAZIONE Alla prima alimentazione del sensore il LED verde lampeggia per circa 10 secondi durante questa fase avviene l autocalibrazione Jumper Range select inserito Per impostare le sensibilità agire sul potenziometro VR1 in senso antiorario e colpire al centro la superficie da pr...

Page 4: ...tallazione Detection led inserito Rosso fisso 3 s Indica la rilevazione di un allarme corretta impostazione della sensibilità in fase di installazione Detection led inserito Arancione fisso 3 s Indica la rilevazione di un colpo molto forte impostazione troppo alta della sensibilità in fase di installazione Detection led inserito CARATTERISTICHE TECNICHE Alimentazione 9 16 Vcc Assorbimento 20mA tip...

Page 5: ...vice main characteristics are the following High sensitivity Configurable detection zone Double sensitivity level False alarm immunity Programmable tri colour led function Very strong hit signal Jam noise indication Low noise opto relay SMT components Analysis card not required INSTALLATION 1 Choose position for sensor installation verify the surface is clean and without roughness NOTE circles ind...

Page 6: ...ONFIGURATION At first power up of the sensor the green LED blinks for approximately 10 seconds and during this time the self calibrating phase is performed Jumper Range select on To set sensitivity turn VR1 trimmer in anticlockwise direction and hit the middle of the surface to be protected If the led lights up red or orange remove selection jumper and select the low sensitivity range low Increase...

Page 7: ...on Red 3 s it indicates an alarm condition right level of sensitivity during installation detection led on Orange 3 s it indicates a very strong hit detection too high sensitivity selection during installation detection led on TECHNICAL SPECIFICATIONS Supply voltage 9 16 Vdc Current consumption 20 mA typical Ripple max 2Vpp 10 Hz 100Hz 12 Vdc Alarm output normally closed switch contact 35 Vdc 100 ...

Page 8: ...atibile contribuisce ad evitare possibili effetti negativi sull ambiente e sulla salute e favorisce il reimpiego e o riciclo dei materiali di cui è composta l apparecchiatura ENGLISH DIRECTIVE 2012 19 EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste electrical and electronic equipment WEEE The symbol of the crossed out wheeled bin on the product or on its packaging indicate...

Reviews: