TRIPLE TECHNOLOGY 

EXTERNAL DETECTOR FOR 

INSTALLATION AT 2.2M

Ref. 1033/146A

DS1033-161A

ENGLISH

10m

10m

5m

0

5m

FIG.1

FIG.2

IR_1

YELLOW

ALARM BLUE

MICROWAVE 

GREEN

IR_2

RED

Tab.1 

Led Displays

Yellow

IR_1

Blue

Alarm

Green

MW

Red

IR_2

FIG.3

2,10 - 2,30 m

0 m

1m

2 m

3 m

4 m

5 m

6 m

7 m

8 m

9 m

10 m

 TECHNICAL SPECIFICATIONS    

Power supply:  

12V   +/- 3V

Max current:

45mA

Standby current:

13mA

Micro wave:

10.525 Ghz

Alarm time:

5 sec

Opto Relay:

100mA/24V

Tamper:

100mA/30V

Working temperature:

-10°C/+55°C

Ambient Humidity: 

95%

Dimensions without 

accessories:

185x85x80mm

• 

Triple technology outdoor detector (two PIR + MW);

• 

 Protection rating IP 54;

• 

 Environmental Class: EN 50131-2-4 CLASS III;

• 

 Protection grade: EN 50131-2-4 GRADE 2;

• 

 Two high-efficiency dual-element PIR sensors with white light filters;

• 

 20 beam Fresnel lenses on 4 layers;

• 

 Active LED antimasking;

• 

 Proximity alert system;

• 

 High quality polycarbonate container, UV stabilized;

• 

 Tropicalized circuit board;

• 

 Dynamic temperature compensation with real ambient temperature 

measurement;

• 

 Pet  immunity.

SPECIFICATIONS AND MAIN FUNCTIONS

PIR 

IR_1

AM 

ACTIVE 

LED

PIR

IR_2

TEMPERATURE 

COMPENSATION

MICROWAVE

FIG.4A

UPPER BRACKET 

FIXING HOLE

FIXING 

TURRET

WALL FIXING BRACKET

LOWER BRACKET 

FIXING HOLE

FIG.4B

INTERFACE 

BOARD

FLAT 

CABLE

DETECTOR BASE

BRACKET 

FIXING 

SCREWS

UPPER 

CLOSING 

SCREW

BRACKET 

FIXING 

SCREWS

END OF LINE 

RESISTANCES

JUMPER M

O-RING

SEALED 

CABLE 

FIG.5A

FIG.5B

DIPSWITCH

INTERFACE 

BOARD 

CONNECTOR

CIRCUIT 

POSITION 

ADJUSTMENT

TRIMMER

FIG.6

WALL 

BRACKET

FLAT CABLE 

CONNECTION 

LED COVER 

LENS

COVER

FIG.7

UPPER CLOSING TAB

LOWER CLOSING TAB

REAR CABLE FEED 

AREA

PRODUCT DESCRIPTION

The 1033/146A detector is a triple-technology device designed and built for the 

protection of outdoor environments where installation is required at a height of 

between 2.10 m and 2.30 m.

It consists of two PASSIVE PYROELECTRIC SENSORS, with Fresnell lenses, 

and a 10.525 GHz MICROWAVE.

The detector has a range of between 3m and 10m.

MAIN FEATURES:

•  high detection efficiency and stability, with dynamic temperature compen

-

sation to prevent false alarms;

•   an ACTIVE  LED  antimasking  system  for  detector  protection  with  a  filter 

possibility through a MW proximity alert system (settable via DIP);

• 

 high immunity to the presence of animals, guaranteed by an algorithm ca-

librated to not detect animals below average size.

WARNINGS 

The following aspects should be considered before installing the 1033/146A 

detector:

• 

the detector must be adjusted so as to prevent its coverage crossing the 

path of moving objects;

•  the ground in the covered area must not have significant slopes (see the 

paragraph on ADJUSTMENT TO THE SLOPE OF THE GROUND);

•  the support on which the detector is mounted must be firm, free from vibra

-

tions and with no unusual protrusions/recesses;

• 

the detector must be positioned so that it is not exposed to direct sunlight;

•  the detector’s coverage area should not include large reflective surfaces, 

such as sheet metal;

•  take care not to obscure the detector’s field of vision with objects, even 

partially;

It should be noted that the best detection condition is when the detection 

lobes intersect the potential intruder’s transit path by 45°.

INSTALLATION HEIGHT

The recommended installation height of the 1033/146A detector is between 

2.10m and 2.30m from the ground. The measurement must be taken from the 

centre of the lens.

FIXING THE DETECTOR

Mount the wall fixing bracket (

FIG.4A

) with appropriate screws and plugs for 

the type of wall; two holes must be drilled aligning with the “Fixing bracket ho-

les” shown in 

FIG.4A

. Fit the O-RINGS (

FIG.4A

) around the cylindrical turrets 

on the wall fixing bracket, in order to prevent infiltration of water through the 

turret holes. After passing the cable through the sealed cable gland (

Fig.4B

on the base, fit the base of the detector to the fixing bracket, aligning the fixing 

turrets on the bracket with the cylindrical holes on the base. Secure the base 

to the bracket with the 4 bracket fixing screws, inserting them from inside the 

base.

To complete the installation, after making the connections, slide the detec-

tor towards the upper closing screw and apply slight pressure at the bottom 

(

FIG.7

). Tighten the upper and lower screws to enable complete closure of the 

detector.

CONNECTIONS 

Wire the system cable to the terminal on the interface board, according to 

the indications given in 

FIG.8

. Make the electrical connections as indicated in 

FIG.8

. Make the electrical connections as indicated in 

FIG.8

.

The end-of-line resistors can be selected for double or triple balance via the 2 

jumpers ALL EOL 1-4 and TAMP EOL 1-4 and jumper M (

FIG.9

). The resistors 

are connected as in the diagram in 

FIG.9A

. The line from the central unit is 

connected with one pole to the <L-> terminal and the other to the <L+ ALL> or 

the <L+ MASK> terminal. With jumper M closed and <L+ MASK> connected, 

the Mask contact is in series with the Alarm contact. In this condition, a resi-

stor of the value required by the control unit (R3B) can be applied to the MASK 

terminal to obtain triple balance. If no resistor is selected and Jumper M is 

open, the contacts are all independent.

Once the necessary adjustments have been made, close the detector by ti-

ghtening the 2 provided screws (one in the upper part just below the rain 

cover, and one in the lower part near the sensor closing profile).

TERMINAL BOARD

INPUT:  AUX input

+

12V power supply input

-

TAMP

Tamper Normally closed

ALL 

Alarm Relay Normally closed

MASK

Antimask Relay Normally closed

FIG.8

Jumper M

1

1

2

2

3

3

4

4

JUMPER M (Alarm/AM), if inserted, puts the alarm 

relay in series with the antimasking relay.

INITIAL POWER-UP

When the power is switched on, the sensor starts the initialization phase, du-

ring which the 3 LEDs blink alternately. After this phase (which lasts about 60 

seconds), the sensor goes into Walk Test mode for 20 minutes.

FIG.9