background image

   

______________________________________________________________________ 

United Renewable Energy Co., Ltd. 

Page  9  of  12 

Warranty

 

 

Ingestion

: Induce vomiting, and seek medical attention. 

Wet Batteries

 

If the battery pack is wet or submerged in water, do not let people access it then contact URE 

or an authorized dealer for technical support. 

Damaged Battery

 

Damaged batteries are dangerous and must be handled with the utmost care. 

They are not fit for use and may pose a danger to people or property. 

If the battery pack seems to be damaged, pack it in its original container, and then return it to 

URE or an authorized dealer. 

NOTE: Damaged batteries may leak electrolyte or produce flammable gas. If such a 

damage occurs, immediately contact URE. 

6.

 

Warranty

 

 

Warranty 

Products that are operated strictly in accordance with the user manual and the URE 
Installation Manual are covered by the warranty. Any violation of this manual may 
void the warranty.

 

 

Limitation of Liability 

Any product damage or property loss caused by the following conditions URE does not assume 

any direct or indirect liability.

 

 

P

roduct modified, design changed or parts replaced without URE authorization;   

 

Changes,  or  attempted  repairs  and  erasing  of  series  number  or  seals  by  non  URE 

technician;   

 

System design and installation are not in compliance with standards and regulations;     

 

The Product has been improperly stored in 

dealer’s or end user’s premises;   

 

Transport  damage  (including  painting  scratch  caused  by  movement  inside  packaging 

during shipping). A claim should be made directly to shipping or insurance company as soon 

as the container/packaging is unloaded and such damage is identified;   

 

Failure  to  follow  any/all  of  the  user  manual,  the  installation  guide  and  the  maintenance 

regulations;   

 

Improper use or misuse of the device;   

Summary of Contents for MA1-BAT

Page 1: ...User Manual Battery Module MA1 BAT V01 ...

Page 2: ......

Page 3: ..._________________________ United Renewable Energy Co Ltd Page 1 of 12 IMPRINT IMPRINT United Renewable Energy Co Ltd Tel 886 3 5780011 Fax 886 3 5781255 Add No 7 Li Hsin 3rd Rd Hsinchu Science Park Hsinchu 30078 Taiwan E mail Ess sales urecorp com ...

Page 4: ...This manual is under the copyright of United Renewable Energy Co Ltd with all rights reserved Please keep the manual properly and operate in strict accordance with all safety and operating instructions in this manual Please do not operate the system before reading through the manual Version Information Version Date Content V01 June 24th 2019 First edition ...

Page 5: ...nt IMPRINT 1 Copyright Statement 2 Version Information 2 Content 3 1 Safety Precautions 4 2 Introduction 4 Features 4 Specifications 5 3 Switch On Off and Display 5 Switch On Off 5 LED Display 5 4 Error and Protection Code 6 Protection Code 6 Error Code 7 5 Emergency Situations 8 6 Warranty 9 Warranty 9 Limitation of Liability 9 ...

Page 6: ...hin 0 C 35 C range Please avoid contact with corrosive substances and keep its distance from fire and heat source The battery SOC is 30 before shipment from the factory For batteries that will not be used for a long time they should be fully charged and discharged at least one time every 6 months Do not install the battery in any environment of temperature below 10 C or over 50 C and humidity over...

Page 7: ...Off System shall be turned on in the correct sequence to avoid any damage Figure 2 MA1 BAT Switch Switch on Pressing the power button for about 2 4 seconds The BMS will start up The LED display and power button will light up as well Switch off Pressing the power button for more than 5 seconds the battery modules will be turned off Figure 3 LED Display LED Display In normal condition LED display in...

Page 8: ...tandby Green light flickering 1 s Work Green light flickering 10s SOC 5 5 SOC 25 25 SOC 50 50 SOC 75 75 SOC 95 SOC 95 4 Error and Protection Code Protection Code LED Ring Protection Code LED Display Description Green light flickering every 3 seconds 1 Temperature difference 3 High temperature 4 Low temperature discharge 5 Over current charge 6 Over current discharge ...

Page 9: ...ardware error Wait for automated recovery In case problem is not resolved call in for repair Error 03 Hardware error Error 05 Hardware error Error 06 Circuit Breaker Open Close circuit breaker after shutting down the battery system Error 07 DIP difference Keep consistence of DIP switches then restart the system Error 08 LMU Disconnect slave Reconnect the communication cable Error 09 SN missing Ent...

Page 10: ...re In case of fire make sure that the following equipment is available near the system SCBA self contained breathing apparatus and protective gear in compliance with the Directive on Personal Protective Equipment 89 686 EEC Novec 1230 FM 200 or dioxide extinguisher NOTE ABC extinguishers are not effective when the battery pack is on fire Batteries may explode when heated above 150 C If possible mo...

Page 11: ... accordance with the user manual and the URE Installation Manual are covered by the warranty Any violation of this manual may void the warranty Limitation of Liability Any product damage or property loss caused by the following conditions URE does not assume any direct or indirect liability Product modified design changed or parts replaced without URE authorization Changes or attempted repairs and...

Page 12: ...e Energy Co Ltd Page 10 of 12 Warranty Insufficient ventilation of the device The maintenance procedures relating to the product have not been followed to an acceptable standard Force majeure violent or stormy weather lightning overvoltage fire etc Damages caused by any external factors ...

Reviews: