4 / 5
b.
Log in and select Console < Select a cluster < Applications < + Add application > Fill
in form < + Add End Device < Fill in Brand, Model, Hardware Version, Software
Version, and Region for your device. (TTS Instructions
Stack for LoRaWAN (thethingsindustries.com)
c.
Enter the JoinEUI/AppEUI, DevEUI and APPKey provided by your manufacturer
2)
Log in to your account on the Urbit Management Center
a.
Select your gateway > Send Command > Add LoRaWAN Sensor > Fill in Sensor Name
(Select a name to identify your sensor), DevEUI, AppEUI, AppKey
b.
The next time your Urb-IoT reports, you should receive data from your sensor. We
recommend you set your sensor and Urb-IoT reporting interval to 5 minutes, until
you make sure is connected, then you can change the reporting interval as needed.
STEP 5: Installation
NOTE: Never paint the Urb-IoT, it could adversely affect the performance of the device and voids all
warranties. Consider the Wi-Fi, BLE, LoRa and Cellular antennas are inside the Urb-IoT
1)
Install your Urb-IoT outdoor as high as possible to ensure radio coverage, ensure there are not
objects colliding or blocking the Urb-IoT
2)
Do not install the Urb-IoT inside a building, under metal surfaces or next to solid or dense
objects (e.g. lush trees), d
on’t block the Urb
-IoT with the post or any other large (metallic)
structure
3)
Select a flat, horizontal mounting location for optimal uniform satellite performance.
**The Urb-IoT must be placed with the logo facing upward.
Figure 1: Urb-IoT installation
4)
The solar panel must be placed below the Urb-IoT, avoid overshadowing the panel with the
equipment. NOTE: DON
’T BLOCK THE SKY VIEW WITH THE SOLAR PANEL., PLACE IT BELOW THE
URB-IOT
Figure 2: Solar Panel mounting
5)
Be sure sensors are placed in a general line of sight of the gateway, face the LoRa Antenna to
the LoRa sensors.