Items
Over-charge protection for each cell
Specification
Content
3.80±0.03V
Over charge
Over-charge release for each cell
3.60±0.05V
Over-charge release method
Under the release voltage
Over-discharge protection for each cell
2.50±0.1V
Over discharge
Over-discharge release for each cell
3.00±0.1V
Over-discharge release method
Charging recovery
Discharge over current protection
650~100A
Over current
Protection delay time
14 - 26ms
Over current release method
Release after cutoff the load
Battery
temperature
Charge over temperature
Protection @55±5°C
Discharge over temperature
Release @55±5°C
Protection @65±5°C
Release @45±5°C
Short
Do not short-circuit the electrodes
Designed For1000A /500us
04
UE-48Li200
Protection @0±5°C
Release @-10±5°C
Protection @-20±5°C
Release @10±5°C
Release @70±5°C
Protection @100±5°C
Charge low temperature
Discharge low temperature
MOSFET over temperature
LCD Screen
Short press a switch, light and display screen: voltage temperature residual capacity
current, light up after waiting for screen to go out, after 60s into power saving state
(buzzer open state, the buzzer alarm detection background), short press it again to light
up the screen.
Buzzer open state: SOC 10% or less, buzzer alarm, long press switch 3s, buzzer close and
screen OFF buzzer hints.
Buzzer is turned off, when the SOC 50% or less, need to manually by 3s starting buzzer
long (SOC testing and determine whether the alarm).
Buzzer is turned off, charging when the battery pack is SOC > 50%, the buzzer closed
automatic reset, in an open position.
Buzz
www.upowerbatteries.com
66A Tzar Asen Srt.
Sofia, Republic of Bulgary
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542
[email protected]