4. Product Performance
5. Protective Circuit Specification
The batteries are supplied with a LiFePO4 Battery Management System (BMS) that can monitor and optimized
each single prismatic cell during charge & discharge, to protect the battery pack overcharge, over discharge,
short circuit. Overall, the BMS helps to ensure safe and accurate running.
NO.
Items
Minimum Capacity
2
3
-20°C
Testing Method
Rated Capacity
1
200Ah
Criteria
Rest for 1 hour after fully charged, then discharge
with 0.33C current until the battery reaches the
discharge cutoff voltage. Repeat above process for
three times, if the discharge time is not less than 120
minutes, you can stop and define the Discharging
current*time value (Ah) as battery capacity.
190Ah
Discharge
Temperature
Characteristics
At 25±5°C discharge the battery with the current of
0.33C to the cut-off voltage and record charge
capacity. Store the battery at various temperatures
for 2h and discharge the battery with 0.33C to the
cut-off voltage.
0°C
25°C
55°C
≥70%
≥80%
≥100%
≥95%
Charge the battery to full capacity and store it for 28
days, and then discharge it with 0.33C to the cut-off
voltage.
Charge Retention
ability
Residual
capacity ≥80%
Internal resistance
≤25mΩ
50% battery SOC state frequency of 1 KHZ ac
resistance tester.
Discharge with the current of 0.33C until it can’t
discharge, and then rest it for 1h. Charge the battery
following CC (0.33C)/CV (14.6V) mode to full capacity,
and then rest it for 1h. Repeat above process until full
charged capacity is no more than 80% of normal
value. Accumulated times is defined as cycle life.
4
Cycle life (DOD%100)
≥2000 cycles
5
6
Recovery
capacity ≥90%
03
UE-48Li200
www.upowerbatteries.com
66A Tzar Asen Srt.
Sofia, Republic of Bulgary
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542
[email protected]