background image

02

NO.

Items

Description 

Length: 150±2mm

Width:   68±2mm

Height:  135±2mm

Dimension

Self-discharge rate

Operating Temperature 

Approx: 2.6±0.5Kg

Charging

0~45°C

Residual capacity

≤3%/month; ≤15%/years

16

17

18

Weight

Discharging

-20~60°C

Recommended operating temperature

15°C~35°C

Reversible capacity

≤1.5%/month; ≤8%/years

Storage Temperature & Humidity Range

Less than 1 month

-20°C~35°C

45% RH~75

% 

RH 

19

Less than 3 months

-10°C~35°C

45% RH~75

% 

RH 

Recommended storage environment

:

15°C~35°C

45% RH~75

% 

RH

15

Long time storage: 
If the battery need be stored for a long time, the voltage should be 26.4V (50% SOC), and stored in the 
condition as storage proposal. It need at least one charge & discharge cycle every six months

3. Test Condition

3.1 Standard Test Conditions

3.1.1 Unless otherwise specified, all performance tests is required conducted at temperature 25°C±2°C,                   
         Humidity less than 45% ~ 75% RH.
3.1.2 Unless otherwise specified, the tested product is required unused within two month after outgoing.

UE-24Li10BL

Maximum discharge current

15A @Battery initial Temp 25±5°C

12

Pulse discharge current

Withstand the 30A/3s

13

20V

14

Discharge cut-off voltage

www.upowerbatteries.com

66A Tzar Asen Srt.
Sofia, Republic of Bulgary
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542
[email protected]