background image

03

NO.

Items

-20°C

Testing method

Internal resistance 

1

≤130mΩ

50% battery SOC state frequency of 1 KHZ ac 

resistance tester. 

Criterion

Discharge 
Temperature 
Characteristics

At 25±5°C discharge the battery with the current of 
0.33C to the cut-off voltage. Store the battery at 
various temperatures for 2h and discharge the 
battery with 0.33C to the cut-off voltage. 

0°C

25°C

55°C

≥70%

≥80%

100%

≥95%

Charge the battery to full capacity and store it for 28 
days, and then discharge it with 0.33C to the cut-off 
voltage.

Charge Retention 
ability

Residual

capacity ≥80%

Discharge with the current of 0.33C until it can’t 
discharge, and then rest it for 1h. Charge the battery 
following CC (0.33C)/CV (14.6V) mode to full capacity, 
and then rest it for 1h. Repeat above process until full 

charged capacity is no more than 80% of normal 

value. Accumulated times is defined as cycle life.

2

Cycle life (DOD%100)

≥2500 cycles

3

UE-24Li10

4. Product Performance

4

Recovery

capacity ≥90%