UE-12Li22BL
03
4. Product Performance
NO.
Items
Minimum Capacity
2
3
-20°C
Testing Method
Rated Capacity
1
22Ah
Criteria
Rest for 1 hour after fully charged, then discharge
with 0.33C current until the battery reaches the
discharge cutoff voltage. Repeat above process for
three times, if the discharge time is not less than 120
minutes, you can stop and define the Discharging
current*time value (Ah) as battery capacity.
21Ah
Discharge
Temperature
Characteristics
At 25±5°C discharge the battery with the current of
0.33C to the cut-off voltage and record charge
capacity. Store the battery at various temperatures
for 2h and discharge the battery with 0.33C to the
cut-off voltage.
0°C
25°C
55°C
≥70%
≥80%
≥100%
≥95%
Charge the battery to full capacity and store it for 28
days, and then discharge it with 0.33C to the cut-off
voltage.
Charge Retention
ability
Residual
capacity ≥80%
Internal resistance
≤50mΩ
50% battery SOC state frequency of 1 KHZ ac
resistance tester.
Discharge with the current of 0.33C until it can’t
discharge, and then rest it for 1h. Charge the battery
following CC (0.33C)/CV (14.6V) mode to full capacity,
and then rest it for 1h. Repeat above process until full
charged capacity is no more than 80% of normal
value. Accumulated times is defined as cycle life.
4
Cycle life (DOD%100)
≥2500 cycles
5
6
Recovery
capacity ≥90%
Though
,
user can read the battery system information
such as voltage, current, SOC, temperature…
and so on.
Communication
Function
Bluetooth
7
3.4 Standard Discharge Mode
"Standard Discharge" means at 25±2°C discharge to the cut-off voltage with 0.33C current.
3.5 Quick Discharge Mode
"Quick Discharge" means discharge to the cut-off voltage with 0.5C current.